Skip to Main Content (Press Enter)

Logo UNISR
  • ×
  • Home
  • Persone
  • Pubblicazioni
  • Facoltà
  • Ambiti Di Ricerca

UNIFIND
Logo UNISR

|

UNIFIND

unisr.it
  • ×
  • Home
  • Persone
  • Pubblicazioni
  • Facoltà
  • Ambiti Di Ricerca
  1. Pubblicazioni

Successful treatment of young infants presenting neonatal diabetes mellitus with continuous subcutaneous insulin infusion before genetic diagnosis

Articolo
Data di Pubblicazione:
2016
Abstract:
Aims: Neonatal diabetes mellitus (NDM) is defined as hyperglycemia and impaired insulin secretion with onset within 6 months of birth. While rare, NDM presents complex challenges regarding the management of glycemic control. The availability of continuous subcutaneous insulin infusion pumps (CSII) in combination with continuous glucose monitoring systems (CGM) provides an opportunity to monitor glucose levels more closely and deliver insulin more safely. Methods: We report four cases of young infants with NDM successfully treated with CSII and CGM. Moreover, in two cases with Kir 6.2 mutation, we describe the use of CSII in switching therapy from insulin to sulfonylurea treatment. Results: Insulin pump requirement for the 4 neonatal diabetes cases was the same regardless of disease pathogenesis and c-peptide levels. No dilution of insulin was needed. The use of an integrated CGM system helped in a more precise control of BG levels with the possibility of several modifications of insulin basal rates. Moreover, as showed in the first two case-reports, when the treatment was switched from insulin to glibenclamide, according to identification of Kir 6.2 mutation and diagnosis of NPDM, the CSII therapy demonstrated to be helpful in allowing gradual insulin suspension and progressive introduction of sulfonylurea. Conclusions: During the neonatal period, the use of CSII therapy is safe, more physiological, accurate and easier for the insulin administration management. Furthermore, CSII therapy is safe during the switch of therapy from insulin to glibenclamide for infants with permanent neonatal diabetes mellitus.
Tipologia CRIS:
1.1 Articolo in rivista
Keywords:
Continuous glucose monitoring systems (CGMS); Continuous subcutaneous insulin infusion pumps (CSII); Hyperglycemia; Neonatal diabetes mellitus
Elenco autori:
Rabbone, I.; Barbetti, F.; Marigliano, M.; Bonfanti, R.; Piccinno, E.; Ortolani, F.; Ignaccolo, G.; Maffeis, C.; Confetto, S.; Cerutti, F.; Zanfardino, A.; Iafusco, D.
Autori di Ateneo:
BONFANTI RICCARDO
Link alla scheda completa:
https://iris.unisr.it/handle/20.500.11768/126674
Pubblicato in:
ACTA DIABETOLOGICA
Journal
  • Utilizzo dei cookie

Realizzato con VIVO | Designed by Cineca | 26.4.5.0