Skip to Main Content (Press Enter)

Logo UNISR
  • ×
  • Home
  • Persone
  • Pubblicazioni
  • Facoltà
  • Ambiti Di Ricerca

UNIFIND
Logo UNISR

|

UNIFIND

unisr.it
  • ×
  • Home
  • Persone
  • Pubblicazioni
  • Facoltà
  • Ambiti Di Ricerca
  1. Pubblicazioni

Five-year results from a randomised controlled trial comparing prostheses supported by 5-mm long implants or by longer implants in augmented bone in posterior atrophic edentulous jaws

Articolo
Data di Pubblicazione:
2019
Citazione:
Five-year results from a randomised controlled trial comparing prostheses supported by 5-mm long implants or by longer implants in augmented bone in posterior atrophic edentulous jaws / Felice, P.; Barausse, C.; Pistilli, R.; Ippolito, D. R.; Esposito, M.. - In: EUROPEAN JOURNAL OF ORAL IMPLANTOLOGY. - ISSN 1756-2406. - 12:1(2019), pp. 25-37.
Abstract:
Purpose: To evaluate whether 5-mm short dental implants could be an alternative to augmentation with anorganic bovine bone and placement of at least 10-mm long implants in posterior atrophic jaws. Materials and methods: Fifteen patients with bilateral atrophic mandibles (5 to 7 mm bone height above the mandibular canal) and 15 patients with bilateral atrophic maxillae (4 to 6 mm bone height below the maxillary sinus), and bone thickness of at least 8 mm, were randomised according to a split-mouth design to receive one to three 5-mm short implants or at least 10-mm long implants in augmented bone. Mandibles were vertically augmented with interpositional bone blocks and maxillary sinuses with particulated bone via a lateral window. Implants were placed after 4 months, submerged and loaded, after another 4 months, with provisional prostheses. Four months later, definitive provisionally cemented prostheses were delivered. Outcome measures were: prosthesis and implant failures, any complication and peri-implant marginal bone level changes. Results: In five augmented mandibles the planned 10-mm long implants could not be placed and shorter implants (7.0 and 8.5 mm) had to be used instead. Five years after loading, six patients, five treated in the mandible and one in the maxilla, dropped out. Three prostheses (one mandibular and two maxillary) failed in the short-implant group versus none in the long-implant group. In mandibles one long implant failed versus two short implants in one patient. In maxillae one long implant failed versus three short implants in two patients. There were no statistically significant differences in implant (n = 26; P = 1.00, difference = 3.85%, 95% CI: -12.95% to 20.64%) and prosthetic (n = 26; P = 0.250, difference = 11.54%, 95% CI: -0.74% to 23.82%) failures. Eleven patients had 16 complications at short implants (one patient accounted for six complications) and 12 patients had 14 complications at long implants. There were no statistically significant differences in complications (n = 28; P = 1.00, difference = -3.57%, 95% CI: -30.65% to 23.51%). Five years after loading, patients with mandibular implants lost on average 1.72 mm at short implants and 2.10 mm at long implants of peri-implant marginal bone. This difference was statistically significant (difference = 0.37 ± 0.43 mm; 95% CI: 0.07 to 0.68 mm; P = 0.022). In maxillae, patients lost on average 1.31 mm at short implants and 1.79 mm at long implants. This difference was statistically significant (difference = 0.48 ± 0.43 mm; 95% CI: 0.22 to 0.74 mm; P = 0.002). Conclusions: Five years after loading, 5-mm short implants achieved similar results to longer implants in augmented bone. The choice of short implants might be preferable to vertical bone augmentation, especially in mandibles, since the treatment is faster and cheaper.
Tipologia CRIS:
1.1 Articolo in rivista
Elenco autori:
Felice, P.; Barausse, C.; Pistilli, R.; Ippolito, D. R.; Esposito, M.
Autori di Ateneo:
ESPOSITO MARCO ANTONIO BRUNO
Link alla scheda completa:
https://iris.unisr.it/handle/20.500.11768/148081
Pubblicato in:
EUROPEAN JOURNAL OF ORAL IMPLANTOLOGY
Journal
  • Dati Generali

Dati Generali

URL

https://www.quintessence-publishing.com/deu/en/article/856015
  • Utilizzo dei cookie

Realizzato con VIVO | Designed by Cineca | 26.5.1.0