Skip to Main Content (Press Enter)

Logo UNISR
  • ×
  • Home
  • Persone
  • Pubblicazioni
  • Facoltà
  • Ambiti Di Ricerca

UNIFIND
Logo UNISR

|

UNIFIND

unisr.it
  • ×
  • Home
  • Persone
  • Pubblicazioni
  • Facoltà
  • Ambiti Di Ricerca
  1. Pubblicazioni

Assessing Diabetic Retinopathy Staging With AI: A Comparative Analysis Between Pseudocolor and LED Imaging

Articolo
Data di Pubblicazione:
2024
Citazione:
Assessing Diabetic Retinopathy Staging With AI: A Comparative Analysis Between Pseudocolor and LED Imaging / Cicinelli, Mv; Gravina, S; Rutigliani, C; Checchin, L; La Franca, L; Lattanzio, R; Bandello, F. - In: TRANSLATIONAL VISION SCIENCE & TECHNOLOGY. - ISSN 2164-2591. - 13:3(2024). [10.1167/tvst.13.3.11]
Abstract:
Purpose: To compare the diagnostic performance of artificial intelligence (AI) -based diabetic retinopathy (DR) staging system across pseudocolor, simulated white light (SWL), and light -emitting diode (LED) camera imaging modalities. Methods: A cross-sectional investigation involved patients with diabetes undergoing imaging with an iCare DRSplus confocal LED camera and an Optos confocal, ultrawidefield pseudocolor camera, with and without SWL. Macula -centered and optic nerve-centered 45 x 45 -degree photographs were processed using EyeArt v2.1. Human graders established the ground truth (GT) for DR severity on dilated fundus exams. Sensitivity and weighted Cohen's weighted kappa (w kappa ) were calculated. An ordinal generalized linear mixed model identified factors influencing accurate DR staging. Results: The study included 362 eyes from 189 patients. The LED camera excelled in identifying sight -threatening DR stages (sensitivity = 0.83, specificity = 0.95 for proliferative DR) and had the highest agreement with the GT (w kappa = 0.71). The addition of SWL to pseudocolor imaging resulted in decreased performance (sensitivity = 0.33, specificity = 0.98 for proliferative DR; w kappa = 0.55). Peripheral lesions reduced the likelihood of being staged in the same or higher DR category by 80% ( P < 0.001). Conclusions: Pseudocolor and LED cameras, although proficient, demonstrated noninterchangeable performance, with the LED camera exhibiting superior accuracy in identifying advanced DR stages. These findings underscore the importance of implementing AI systems trained for ultra-widefield imaging, considering the impact of peripheral lesions on correct DR staging. Translational Relevance: This study underscores the need for artificial intelligence- based systems specifically trained for ultra-widefield imaging in diabetic retinopathy assessment.
Tipologia CRIS:
1.1 Articolo in rivista
Elenco autori:
Cicinelli, Mv; Gravina, S; Rutigliani, C; Checchin, L; La Franca, L; Lattanzio, R; Bandello, F
Autori di Ateneo:
BANDELLO FRANCESCO
CICINELLI MARIA VITTORIA
Link alla scheda completa:
https://iris.unisr.it/handle/20.500.11768/198125
Link al Full Text:
https://iris.unisr.it//retrieve/handle/20.500.11768/198125/349651/i2164-2591-13-3-11_1710415440.12393.pdf
Pubblicato in:
TRANSLATIONAL VISION SCIENCE & TECHNOLOGY
Journal
  • Utilizzo dei cookie

Realizzato con VIVO | Designed by Cineca | 26.5.1.0