Skip to Main Content (Press Enter)

Logo UNISR
  • ×
  • Home
  • Persone
  • Pubblicazioni
  • Facoltà
  • Ambiti Di Ricerca

UNIFIND
Logo UNISR

|

UNIFIND

unisr.it
  • ×
  • Home
  • Persone
  • Pubblicazioni
  • Facoltà
  • Ambiti Di Ricerca

Cyclic Fatigue Resistance of Four Heat-Treated Nickel-Titanium Files in Severely Curved Simulated Canals: An In Vitro Study

Articolo
Data di Pubblicazione:
2024
Citazione:
Cyclic Fatigue Resistance of Four Heat-Treated Nickel-Titanium Files in Severely Curved Simulated Canals: An In Vitro Study / Greco, Katia; Paolone, Gaetano; Cicero, Giuseppe; Tetè, Giulia; Cantile, Nicola; Sberna, Maria Teresa; Saladino, Teresa; Gherlone, Enrico Felice; Cantatore, Giuseppe. - In: JOURNAL OF CLINICAL MEDICINE. - ISSN 2077-0383. - 13:19(2024). [10.3390/jcm13195739]
Abstract:
: Background: Rotary Ni-Ti files are susceptible to sudden intra-canal separation due to cyclic fatigue stress, particularly in curved canals. To increase resistance to cyclic fatigue, new heat-treated files have been introduced. This study aimed to compare the performance of four heat-treated Ni-Ti files in two simulated curved root canals by evaluating the effect of the alloy, rotation speed, and diameter of the files on their resistance to cyclic fatigue. Methods: The Ni-Ti files included in the study were the ProTaper Gold® (Dentsply Sirona) F2, ProTaper Ultimate® (Dentsply Sirona) F2, FQ® (Komet) 25.06, and Blueshaper® (Zarc4Endo) Z4 25.06. Two groups of 30 files were selected for each system and were tested in two simulated canals milled in a specific metal template. One group was tested in a 60° curved canal and the other in a 90° curved canal. Results: In the 60° simulated canal, there were no instrument fractures within the 15 min time limit. In the 90° simulated canal, the Blueshaper Z4 demonstrated a lower resistance to cyclic fatigue, while FQ 25.06 showed statistically higher fatigue resistance based on both the Kruskal-Wallis and Games-Howell tests (p < 0.05). Conclusions: No differences were found between files when tested in a 60° curved canal for up to 15 min. However, in a 90° canal, the FQ® files showed significantly higher resistance to cyclic fatigue, especially compared to the Blueshaper® Z4. The ProTaper Ultimate and ProTaper Gold produced intermediate results, with the ProTaper Ultimate F2 slightly outperforming the ProTaper Gold F2.
Tipologia CRIS:
1.1 Articolo in rivista
Elenco autori:
Greco, Katia; Paolone, Gaetano; Cicero, Giuseppe; Tetè, Giulia; Cantile, Nicola; Sberna, Maria Teresa; Saladino, Teresa; Gherlone, Enrico Felice; Cantatore, Giuseppe
Autori di Ateneo:
CANTATORE GIUSEPPE
GHERLONE FELICE ENRICO
PAOLONE GAETANO
Link alla scheda completa:
https://iris.unisr.it/handle/20.500.11768/172416
Link al Full Text:
https://iris.unisr.it//retrieve/handle/20.500.11768/172416/253620/jcm-13-05739-with-cover.pdf
Pubblicato in:
JOURNAL OF CLINICAL MEDICINE
Journal
  • Dati Generali

Dati Generali

URL

https://www.mdpi.com/2077-0383/13/19/5739
  • Utilizzo dei cookie

Realizzato con VIVO | Designed by Cineca | 26.5.1.0