Early outcomes of the novel Myval THV series compared to SAPIEN THV series and Evolut THV series in individuals with severe aortic stenosis
Articolo
Data di Pubblicazione:
2025
Citazione:
Early outcomes of the novel Myval THV series compared to SAPIEN THV series and Evolut THV series in individuals with severe aortic stenosis / Van Royen, N.; Amat-Santos, I. J.; Hudec, M.; Bunc, M.; Ijsselmuiden, A.; Laanmets, P.; Unic, D.; Merkely, B.; Hermanides, R. S.; Ninios, V.; Protasiewicz, M.; Rensing, B. J. W. M.; Martin, P. L.; Feres, F.; De Sousa Almeida, M.; Van Belle, E.; Linke, A.; Ielasi, A.; Montorfano, M.; Webster, M.; Toutouzas, K.; Teiger, E.; Bedogni, F.; Voskuil, M.; Pan, M.; Angeras, O.; Kim, W. -K.; Rothe, J.; Kristic, I.; Peral, V.; Van Den Branden, B. J. L.; Westermann, D.; Bellini, B.; Garcia-Gomez, M.; Tobe, A.; Tsai, T. -Y.; Garg, S.; Thakkar, A.; Chandra, U.; Morice, M. -C.; Soliman, O.; Onuma, Y.; Serruys, P. W.; Baumbach, A.. - In: EUROINTERVENTION. - ISSN 1774-024X. - 21:2(2025), pp. 105-118. [10.4244/EIJ-D-24-00951]
Abstract:
BACKGROUND: There are limited head-to-head randomised trials comparing the performance of different transcatheter heart valves (THVs). AIMS: We aimed to evaluate the non-inferiority of the balloon-expandable Myval THV series compared to the balloon-expandable SAPIEN THV series or the self-expanding Evolut THV series. METHODS: The LANDMARK trial randomised 768 patients in a 1:1 ratio, (Myval THV series [n=384] vs contemporary series with 50% SAPIEN THV series [n=192] and 50% Evolut THV series [n=192]). The non-inferiority of Myval over the SAPIEN or Evolut THV series in terms of the 30-day primary composite safety and effectiveness endpoint as per the third Valve Academic Research Consortium (VARC-3) was tested in an intention-to-treat population with a predefined statistical power of 80% (1-sided alpha of 5%) for a non-inferiority margin of 10.44%. RESULTS: The Myval THV series achieved non-inferiority for the primary composite endpoint over the SAPIEN THV series (24.7% vs 24.1%, risk difference [95% confidence interval {CI}]: 0.6% [not applicable {NA} to 8.0]; p=0.0033) and the Evolut THV series (24.7% vs 30.0%, risk difference [95% CI]: –5.3% [NA to 2.5]; p<0.0001). The incidences of pacemaker implantation were comparable (Myval THV series: 15.0%, SAPIEN THV series: 17.3%, Evolut THV series: 16.8%). At 30 days, the mean pressure gradient and effective orifice area were significantly better with the Myval THV series compared to the SAPIEN THV series (p<0.0001) and better with the Evolut THV series than with the Myval THV series (p<0.0001). At 30 days, the proportion of moderate to severe prosthetic valve regurgitation was numerically higher with the Evolut THV series compared to the Myval THV series (7.4% vs 3.4%; p=0.06), while not significantly different between the Myval THV series and the SAPIEN THV series (3.4% vs 1.6%; p=0.32). CONCLUSIONS: The Myval THV series is non-inferior to the SAPIEN THV series and the Evolut THV series in terms of the primary composite endpoint at 30 days.
Tipologia CRIS:
1.1 Articolo in rivista
Elenco autori:
Van Royen, N.; Amat-Santos, I. J.; Hudec, M.; Bunc, M.; Ijsselmuiden, A.; Laanmets, P.; Unic, D.; Merkely, B.; Hermanides, R. S.; Ninios, V.; Protasiewicz, M.; Rensing, B. J. W. M.; Martin, P. L.; Feres, F.; De Sousa Almeida, M.; Van Belle, E.; Linke, A.; Ielasi, A.; Montorfano, M.; Webster, M.; Toutouzas, K.; Teiger, E.; Bedogni, F.; Voskuil, M.; Pan, M.; Angeras, O.; Kim, W. -K.; Rothe, J.; Kristic, I.; Peral, V.; Van Den Branden, B. J. L.; Westermann, D.; Bellini, B.; Garcia-Gomez, M.; Tobe, A.; Tsai, T. -Y.; Garg, S.; Thakkar, A.; Chandra, U.; Morice, M. -C.; Soliman, O.; Onuma, Y.; Serruys, P. W.; Baumbach, A.
Link alla scheda completa:
Link al Full Text:
Pubblicato in: