Assessment of Image Quality Performance of a Photon-Counting Computed Tomography Scanner Approved for Whole-Body Clinical Applications

Articolo
Data di Pubblicazione:
2025
Citazione:
Assessment of Image Quality Performance of a Photon-Counting Computed Tomography Scanner Approved for Whole-Body Clinical Applications / Maddaloni, F. S.; Sarno, A.; Loria, A.; Piai, A.; Lenardi, C.; Esposito, A.; Del Vecchio, A.. - In: SENSORS. - ISSN 1424-8220. - 25:23(2025). [10.3390/s25237338]
Abstract:
Background: Photon-counting computed tomography (PCCT) represents a major technological advance in clinical CT imaging, offering superior spatial resolution, enhanced material discrimination, and potential radiation dose reduction compared to conventional energy-integrating detector systems. As the first clinically approved PCCT scanner becomes available, establishing a comprehensive characterization of its image quality is essential to understand its performance and clinical impact. Methods: Image quality was evaluated using a commercial quality assurance phantom with acquisition protocols typically used for three anatomical regions—head, abdomen/thorax, and inner ear—representing diverse clinical scenarios. Each region was scanned using both ultra-high-resolution (UHR, 120 × 0.2 mm slices) and conventional (144 × 0.4 mm slices) protocols. Conventional metrics, including signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), slice thickness accuracy, and uniformity, were assessed following international standards. Task-based analysis was also performed through target transfer function (TTF), noise power spectrum (NPS), and detectability index (d′) to evaluate diagnostic relevance. Results: UHR protocols provided markedly improved spatial resolution, particularly in the inner ear imaging, as confirmed by TTF analysis, though with increased noise and reduced low-contrast detectability in certain conditions. CT numbers showed linear correspondence with known attenuation coefficients across all protocols. Conclusions: This study establishes a detailed technical characterization of the first clinical PCCT scanner, demonstrating significant improvements in terms of spatial resolution and accuracy of the quantitative image analysis, while highlighting the need for noise–contrast optimization in high-resolution imaging.
Tipologia CRIS:
1.1 Articolo in rivista
Elenco autori:
Maddaloni, F. S.; Sarno, A.; Loria, A.; Piai, A.; Lenardi, C.; Esposito, A.; Del Vecchio, A.
Autori di Ateneo:
ESPOSITO ANTONIO
Link alla scheda completa:
https://iris.unisr.it/handle/20.500.11768/194916
Link al Full Text:
https://iris.unisr.it//retrieve/handle/20.500.11768/194916/339494/sensors-25-07338-v2.pdf
Pubblicato in:
SENSORS
Journal
  • Dati Generali

Dati Generali

URL

https://www.mdpi.com/1424-8220/25/23/7338
  • Utilizzo dei cookie

Realizzato con VIVO | Designed by Cineca | 26.5.2.0