  1. Pubblicazioni

Continuous Glucose Monitoring and Automated Insulin Delivery in Infants with Type 1 Diabetes: Real-World Evidence to Support Future International Guidelines

Articolo
Data di Pubblicazione:
2026
Citazione:
Continuous Glucose Monitoring and Automated Insulin Delivery in Infants with Type 1 Diabetes: Real-World Evidence to Support Future International Guidelines / Marigliano, M., Scaramuzza, A.E., Arnaldi, C., Bonfanti, R., Cherubini, V., Franceschi, R., Lombardo, F., Maltoni, G., Mozzillo, E., Bassi, M., Rabbone, I., Schiaffini, R., Tiberi, V., Tinti, D., Maffeis, C.. - In: DIABETES TECHNOLOGY & THERAPEUTICS. - ISSN 1520-9156. - (2026). [10.1177/15209156261479814]
Abstract:
To evaluate efficacy and safety of continuous glucose monitoring (CGM) and automated insulin delivery (AID) in infants. A retrospective multicenter study (13 centers) of 76 children diagnosed with antibody-positive type 1 diabetes before age 2. Outcomes at 12 months were compared between AID users (n = 47) and multiple daily injections (MDI)/SAP users (n = 29). AID systems included Medtronic 780 G (38%), Tandem Control-IQ (38%), and CamAPS FX (24%). CGM median wear time was 97.0% (93.3; 98.1). AID users achieved significantly higher TIR (65% vs. 56%, P = 0.041) and time in tight range (TITR) (42% vs 32.5%, P = 0.038). In multivariable regression, AID was the sole independent predictor of lower HbA1c (P = 0.035). Zero severe hypoglycemia (SH) events occurred in the AID group (vs. 7.1% in MDI/SAP). Use of CGM is safe in very young children, with AID systems proving superior to traditional therapy. This real-world evidence supports incorporating AID consideration into future international guidelines from the time of pediatric diagnosis.
Tipologia CRIS:
1.1 Articolo in rivista
Keywords:
automated insulin delivery; continuous glucose monitoring; hypoglycemia; infants; time in range; type 1 diabetes
Elenco autori:
Marigliano, M.; Scaramuzza, A. E.; Arnaldi, C.; Bonfanti, R.; Cherubini, V.; Franceschi, R.; Lombardo, F.; Maltoni, G.; Mozzillo, E.; Bassi, M.; Rabbone, I.; Schiaffini, R.; Tiberi, V.; Tinti, D.; Maffeis, C.
Autori di Ateneo:
BONFANTI RICCARDO
Link alla scheda completa:
https://iris.unisr.it/handle/20.500.11768/206678
Pubblicato in:
DIABETES TECHNOLOGY & THERAPEUTICS