Durable ventricular assist device implantation after acute myocardial infarction: an analysis of the EUROMACS registry

Articolo
Data di Pubblicazione:
2026
Citazione:
Durable ventricular assist device implantation after acute myocardial infarction: an analysis of the EUROMACS registry / Pieri, M., Altizio, S., Pontillo, D., Schoenrath, F., Consolo, F., Ajello, S., Scandroglio, A.M.. - In: JOURNAL OF CARDIOVASCULAR MEDICINE. - ISSN 1558-2027. - 27:7(2026), pp. 579-586. [10.2459/JCM.0000000000001911]
Abstract:
Introduction – Patients undergoing durable ventricular assist device (VAD) implantation after acute myocardial infarction (AMI) present critical surgical and clinical challenges. Data on outcomes in this high-risk population remain limited. The aim of this study was to describe the clinical profile and identify predictors of long-term outcomes in AMI patients receiving durable VAD support. Methods – Retrospective analysis of patients included in the EUROMACS registry (1995–2024) was conducted. Results – Three hundred and thirty-five patients (4.8% of EUROMACS records) underwent VAD implantation post-AMI. Most patients presented with severe cardiogenic shock (82% INTERMACS class 1–2), and the median time from AMI hospitalization to VAD implantation was 9 (IQR 8–14) days. Surgical revision for bleeding was required in 20% of patients. Mortality risk was 31% at 1 year, 46% at 5 years and 56% at 10 years. At multivariable analysis, female sex [subdistribution hazard ratio (SHR): 2.70, 95% confidence interval (95% CI): 1.62–4.49, P = 0.016], mechanical ventilation (SHR: 2.16, 95% CI: 1.44–3.26, P < 0.001) and VAD implantation as destination therapy (SHR: 2.48, 95% CI: 1.69–3.64, P < 0.001) were independent predictors of mortality, while a recent year of implant (SHR: 0.84, 95% CI: 0.73–0.97, P = 0.016) increasing BMI (SHR: 0.96, 95% CI: 0.94–0.99, P = 0.014), no previous history of heart failure (SHR: 0.61, 95% CI: 0.42–0.91, P = 0.014) and the presence of sinus rhythm (SHR: 0.63, 95% CI: 0.43–0.92, P = 0.017) were protective factors against mortality. Conclusion – AMI patients accounted for a small subset of durable VAD recipients in an all-comers international registry, with high cardiogenic shock severity and substantial mortality risk. These findings provide a rationale for future prospective studies aimed at optimizing management and outcomes in this vulnerable population.
Tipologia CRIS:
1.1 Articolo in rivista
Elenco autori:
Pieri, M.; Altizio, S.; Pontillo, D.; Schoenrath, F.; Consolo, F.; Ajello, S.; Scandroglio, A. M.
Autori di Ateneo:
CONSOLO FILIPPO
PIERI MARINA LAURA GRAZIA
SCANDROGLIO ANNA MARA
Link alla scheda completa:
https://iris.unisr.it/handle/20.500.11768/210316
Pubblicato in:
JOURNAL OF CARDIOVASCULAR MEDICINE
Journal
  • Utilizzo dei cookie

Realizzato con VIVO | Designed by Cineca | 26.11.1.0