Feasibility of Protective Ventilation During Elective Supratentorial Neurosurgery: A Randomized, Crossover, Clinical Trial

Articolo
Data di Pubblicazione:
2018
Abstract:
BACKGROUND:: Traditional ventilation approaches, providing high tidal volumes (Vt), produce excessive alveolar distention and lung injury. Protective ventilation, employing lower Vt and positive end-expiratory pressure (PEEP), is an attractive alternative also for neuroanesthesia, when prolonged mechanical ventilation is needed. Nevertheless, protective ventilation during intracranial surgery may exert dangerous effects on intracranial pressure (ICP). We tested the feasibility of a protective ventilation strategy in neurosurgery. MATERIALS AND METHODS:: Our monocentric, double-blind, 1:1 randomized, 2×2 crossover study aimed at studying the effect size and variability of ICP in patients undergoing elective supratentorial brain tumor removal and alternatively ventilated with Vt 9 mL/kg—PEEP 0 mm Hg and Vt 7 mL/kg—PEEP 5 mm Hg. Respiratory rate was adjusted to maintain comparable end-tidal carbon dioxide between ventilation modes. ICP was measured through a subdural catheter inserted before dural opening. RESULTS:: Forty patients were enrolled; 8 (15%) were excluded after enrollment. ICP did not differ between traditional and protective ventilation (11.28±5.37, 11 [7 to 14.5] vs. 11.90±5.86, 11 [8 to 15] mm Hg; P=0.541). End-tidal carbon dioxide (28.91±2.28, 29 [28 to 30] vs. 28.00±2.17, 28 [27 to 29] mm Hg; P<0.001). Peak airway pressure (17.25±1.97, 17 [16 to 18.5] vs. 15.81±2.87, 15.5 [14 to 17] mm Hg; P<0.001) and plateau airway pressure (16.06±2.30, 16 [14.5 to 17] vs. 14.19±2.82, 14 [12.5 to 16] mm Hg; P<0.001) were higher during protective ventilation. Blood pressure, heart rate, and body temperature did not differ between ventilation modes. Dural tension was “acceptable for surgery†in all cases. ICP differences between ventilation modes were not affected by ICP values under traditional ventilation (coefficient=0.067; 95% confidence interval, −0.278 to 0.144; P=0.523). CONCLUSIONS:: Protective ventilation is a feasible alternative to traditional ventilation during elective neurosurgery.
Tipologia CRIS:
1.1 Articolo in rivista
Keywords:
Surgery; Neurology (clinical); Anesthesiology and Pain Medicine
Elenco autori:
Ruggieri, Francesco; Beretta, Luigi; Corno, Laura; Testa, Valentina; Martino, Enrico A.; Gemma, Marco
Autori di Ateneo:
BERETTA LUIGI
Link alla scheda completa:
https://iris.unisr.it/handle/20.500.11768/65236
Pubblicato in:
JOURNAL OF NEUROSURGICAL ANESTHESIOLOGY
Journal
  • Dati Generali

Dati Generali

URL

http://journals.lww.com/jnsa
  • Utilizzo dei cookie

Realizzato con VIVO | Designed by Cineca | 26.5.1.0