Skip to Main Content (Press Enter)

Logo UNISR
  • ×
  • Home
  • Persone
  • Pubblicazioni
  • Facoltà
  • Ambiti Di Ricerca

UNIFIND
Logo UNISR

|

UNIFIND

unisr.it
  • ×
  • Home
  • Persone
  • Pubblicazioni
  • Facoltà
  • Ambiti Di Ricerca
  1. Pubblicazioni

Endoscopic ultrasound-guided application of a new hybrid cryotherm probe in porcine pancreas: A preliminary study

Articolo
Data di Pubblicazione:
2008
Citazione:
Endoscopic ultrasound-guided application of a new hybrid cryotherm probe in porcine pancreas: A preliminary study / Carrara, S; Arcidiacono, Pg; Albarello, L; Addis, A; Enderle, Md; Boemo, C; Neugebauer, A; Campagnol, M; Doglioni, Claudio; Testoni, Pier Alberto. - In: ENDOSCOPY. - ISSN 0013-726X. - 40:9(2008), pp. 759-763. [10.1055/s-2008-1077520]
Abstract:
Background and study aims: In a previous study, a new flexible bipolar hybrid cryotherm probe was applied with success to the pancreas of a living pig. Here we evaluated feasibility, efficacy, and safety of its application to the porcine liver and spleen. Material and methods: Ten applications to the liver and nine to the spleen were performed in 19 pigs. Power input (16 - 18 W) and simultaneous cooling with CO(2) (standardized pressure: 675psi) as the cryogenic agent were investigated. Application time varied from 120 seconds to 900 seconds. The ablation area was measured by endoscopic ultrasound (EUS) after ablation (T0), and before euthanasia (T1). Gross pathology (T2) and histology after necropsy represented the gold standard. The interval from treatment to euthanasia was 1 or 2 weeks. Results: For both organs the correlation between EUS and gross pathology was good (correlation coefficient R(liver) = 0.71; R(spleen) = 0.73). EUS tended to overestimate the area of the ablated zone. EUS observed a time-dependent ablation area: we demonstrated a positive trend of lesion size (T1) over time in liver tissue (R = 0.51 (P = 0.1)). In the spleen we found a clear correlation of lesion area T2 and application time (R = 0.75, P = 0.01). There were no complications. Conclusions: Selective EUS-guided transgastric cryotherm ablation of the liver and spleen in a pig model is feasible and safe. The new bipolar probe creates a time-dependent ablation area without any complications, and opens a field of new potential indications of RF-ablative therapies. ZB 0 ZR 0 ZS 0 Z8 2
Tipologia CRIS:
1.1 Articolo in rivista
Elenco autori:
Carrara, S; Arcidiacono, Pg; Albarello, L; Addis, A; Enderle, Md; Boemo, C; Neugebauer, A; Campagnol, M; Doglioni, Claudio; Testoni, Pier Alberto
Autori di Ateneo:
ARCIDIACONO PAOLO GIORGIO
Link alla scheda completa:
https://iris.unisr.it/handle/20.500.11768/95607
Pubblicato in:
ENDOSCOPY
Journal
  • Utilizzo dei cookie

Realizzato con VIVO | Designed by Cineca | 26.5.1.0