Skip to Main Content (Press Enter)

Logo UNISR
  • ×
  • Home
  • Persone
  • Pubblicazioni
  • Facoltà
  • Ambiti Di Ricerca

UNIFIND
Logo UNISR

|

UNIFIND

unisr.it
  • ×
  • Home
  • Persone
  • Pubblicazioni
  • Facoltà
  • Ambiti Di Ricerca
  1. Pubblicazioni

When assistive eye tracking fails: Communicating with a brainstem-stroke patient through the pupillary accommodative response – A case study

Articolo
Data di Pubblicazione:
2021
Citazione:
When assistive eye tracking fails: Communicating with a brainstem-stroke patient through the pupillary accommodative response – A case study / Lorenzo Villalobos, A.E., Giusiano, S., Musso, L., De'Sperati, C., Riberi, A., Spalek, P., Calvo, A., Moglia, C., Roatta, S.. - In: BIOMEDICAL SIGNAL PROCESSING AND CONTROL. - ISSN 1746-8094. - 67:(2021). [10.1016/j.bspc.2021.102515]
Abstract:
Purpose: Poor control of eye movement and coordination may impair the use of eye-trackers for communication in patients affected by severe motor diseases. Recently, the “voluntary” pupil accommodative response (PAR) was suggested as a possible alternative to traditional assistive technology. Aim of this study is to provide a proof of concept of this methodology in a clinical setting. Materials and methods: A low-cost communication system was implemented, which detects the accommodative pupillary constrictions in real time and generates trigger events to drive a commercial scanning-selection interface. As a first implementation, a simple binary yes/no selection interface was designed to be tested with a brainstem stroke patient, unable to use standard communicators based on eye tracking. The patient was instructed to operate the intended selection by switching the focus of attention from a far to a near target, and was then presented with 10 questions with obvious answer. Results: The patient easily understood how to perform the accommodative task. The pupillary constrictions were marked and clearly detectable in spite of the disturbing action of persistent nystagmus. On the first presentation of the device, the patient managed to correctly answer 8 out of 10 questions. Conclusions: The present results provide a proof-of-concept for PAR-based communication in a clinical setting and support its usefulness with patients who, due to impaired control of eye movements, may be unable to use tracking-based devices.
Tipologia CRIS:
1.1 Articolo in rivista
Elenco autori:
Lorenzo Villalobos, A. E.; Giusiano, S.; Musso, L.; De'Sperati, C.; Riberi, A.; Spalek, P.; Calvo, A.; Moglia, C.; Roatta, S.
Autori di Ateneo:
DE'SPERATI CLAUDIO
Link alla scheda completa:
https://iris.unisr.it/handle/20.500.11768/117832
Link al Full Text:
https://iris.unisr.it//retrieve/handle/20.500.11768/117832/276858/Villalobos%20et%20al%202021%20(BSPC).pdf
Pubblicato in:
BIOMEDICAL SIGNAL PROCESSING AND CONTROL
Journal
  • Dati Generali

Dati Generali

URL

https://www.sciencedirect.com/science/article/abs/pii/S1746809421001129?via=ihub
  • Utilizzo dei cookie

Realizzato con VIVO | Designed by Cineca | 26.7.2.0