Skip to Main Content (Press Enter)

Logo UNISR
  • ×
  • Home
  • Persone
  • Pubblicazioni
  • Facoltà
  • Ambiti Di Ricerca

UNIFIND
Logo UNISR

|

UNIFIND

unisr.it
  • ×
  • Home
  • Persone
  • Pubblicazioni
  • Facoltà
  • Ambiti Di Ricerca
  1. Pubblicazioni

Insertion and removal torque of dental implants placed using different drilling protocols: An experimental study on artificial bone substitutes

Articolo
Data di Pubblicazione:
2023
Citazione:
Insertion and removal torque of dental implants placed using different drilling protocols: An experimental study on artificial bone substitutes / Romeo, D., Chochlidakis, K., Barmak, A.B., Agliardi, E., Lo Russo, L., Ercoli, C.. - In: JOURNAL OF PROSTHODONTICS. - ISSN 1059-941X. - 32:7(2023), pp. 633-638. [10.1111/jopr.13607]
Abstract:
Purpose: The aim of this in vitro study was to measure the insertion and removal torque values of dental implant replicas inserted into artificial bone blocks using different surgical burs and drilling protocols. Materials and methods: Four types of artificial, polyurethane bone blocks were used with different thicknesses (1 and 2 mm) and densities (soft-1 mm, soft-2 mm, dense-1 mm, and dense-2 mm) of the simulated cortical and cancellous bone, respectively. Each bone construct was drilled with Straumann and Densah drills in both clockwise and counterclockwise directions for a total of 16 experimental conditions. For every scenario, 38 implant replicas were inserted and then removed after 1 min. Outcomes of interest were the insertion and removal torque values which were recorded by a torque meter. ANOVA and Tukey HSD tests were used to assess differences across each combination of drill, direction, and bone type. Results: Densah counterclockwise registered statistically greater values for both insertion and removal torque, followed by Densah clockwise, Straumann counterclockwise, and Straumann clockwise. Increasing insertion and removal torque values were progressively reported for bone type (soft-1 mm, dense-1 mm, soft-2 mm, and dense-2 mm). The mean values of insertion and removal torque were significantly different (p < 0.05) across the four bone types, different burs, and with the two drilling modalities. Conclusions: Densah bur resulted in significantly greater values of torque compared to the Straumann drills for all the experimental conditions. The thickness of the cortical layer and the counterclockwise drilling direction play a significant role in determining the implant insertion torque.
Tipologia CRIS:
1.1 Articolo in rivista
Elenco autori:
Romeo, D.; Chochlidakis, K.; Barmak, A. B.; Agliardi, E.; Lo Russo, L.; Ercoli, C.
Autori di Ateneo:
AGLIARDI ENRICO LUIGI
Link alla scheda completa:
https://iris.unisr.it/handle/20.500.11768/136162
Pubblicato in:
JOURNAL OF PROSTHODONTICS
Journal
  • Dati Generali

Dati Generali

URL

https://onlinelibrary.wiley.com/doi/10.1111/jopr.13607
  • Utilizzo dei cookie

Realizzato con VIVO | Designed by Cineca | 26.5.2.0