Citazione:
Validation of predictors of intraprocedural stent thrombosis in the drug-eluting stent era / Biondi-Zoccai Giuseppe, G.L., Sangiorgi Giuseppe, M., Chieffo, A., Vittori, G., Falchetti, E., Margheri, M., Barbagallo, R., Tamburino, C., Remigi, E., Briguori, C., Iakovou, I., Agostoni, P., Tsagalou, E., Melzi, G., Michev, I., Airoldi, F., Montorfano, M., Carlino, M., Colombo, A.. - In: THE AMERICAN JOURNAL OF CARDIOLOGY. - ISSN 0002-9149. - (2005). [10.1016/j.amjcard.2005.01.099]
Abstract:
Although predictors of acute intraprocedural stent thrombosis (IPST) in the drug-eluting stent era have been proposed, external validation is lacking. We thus analyzed the occurrence of IPST in the RECIPE study and found that, among 1,320 patients who underwent drug-eluting stent implantation, IPST occurred in 6 (0.5%), with in-hospital major adverse events in 4 (67%). IPST was predicted by number and total length of implanted stents, baseline minimal lumen diameter, and, in a pooled analysis that incorporated values from the present study and a previous study, use of elective glycoprotein IIb/IIIa inhibitors. Such results may provide useful information to guide prevention of this complication.
Tipologia CRIS:
1.1 Articolo in rivista
Elenco autori:
Biondi-Zoccai Giuseppe, G. L.; Sangiorgi Giuseppe, M.; Chieffo, Alaide; Vittori, Guido; Falchetti, Elena; Margheri, Massimo; Barbagallo, Rossella; Tamburino, Corrado; Remigi, Enrico; Briguori, Carlo; Iakovou, Ioannis; Agostoni, Pierfrancesco; Tsagalou, Elephteria; Melzi, Gloria; Michev, Iassen; Airoldi, Flavio; Montorfano, M; Carlino, Mauro; Colombo, Antonio