Computed tomography or contrast-enhanced ultrasonography for follow-up of liver metastases after Cyberknife therapy?: A prospective pilot study

Articolo
Data di Pubblicazione:
2019
Citazione:
Computed tomography or contrast-enhanced ultrasonography for follow-up of liver metastases after Cyberknife therapy?: A prospective pilot study / Marsico, M., Gabbani, T., Lunardi, S., Lei, B., Lucarini, M., Cuffari, B., Curatolo, A., Biagini, M.R., Annese, V.. - In: JOURNAL OF ULTRASOUND IN MEDICINE. - ISSN 1550-9613. - 38:3(2019), pp. 649-655. [10.1002/jum.14734]
Abstract:
Objectives: Contrast-enhanced ultrasonography (CEUS) allows the study of vascularization of secondary liver lesions. The Cyberknife (Accuray, Inc, Sunnyvale, CA) is a therapeutic method that allows a tumor target to be subjected to a high radiant dose gradient. This prospective pilot study aimed to demonstrate the concordance of CEUS versus contrast-enhanced computed tomography (CECT) in determining the stability or disease progression of secondary liver lesions after treatment with the Cyberknife. Methods: Twenty-four patients were consecutively enrolled, and 3 different operators evaluated the CEUS images and the intermodality concordance with CECT. All patients received CEUS at 1 and 2 months after the Cyberknife therapy. The intermodality agreement was evaluated by the Cohen κ coefficient and a multivariate analysis according to the method of Janson and Olsson (Educ Psychol Meas 2001; 61:277-289). Results: Forty secondary liver lesions were detected and treated. Forty-one CECT and 51 CEUS examinations were performed without any adverse events in the 24 patients. The intermodality agreement rates, calculated for the operators as Cohen κ values, were κ = 1.00, 0.881, and 0.767, respectively. The multivariate analysis of intermodality agreement showed an almost perfect value (ι = 0.841). Conclusions: This pilot study found excellent diagnostic correspondence between CEUS and CECT in the evaluation of local disease stability or progression after Cyberknife therapy in liver metastases. These findings suggest that CEUS could play an important role in the surveillance of these patients because of its high accuracy and reproducibility, thus reducing the need for CECT.
Tipologia CRIS:
1.1 Articolo in rivista
Elenco autori:
Marsico, Maria; Gabbani, Tommaso; Lunardi, Sarah; Lei, Barbara; Lucarini, Matteo; Cuffari, Biagio; Curatolo, Angela; Biagini, Maria Rosa; Annese, Vito
Autori di Ateneo:
ANNESE VITO
Link alla scheda completa:
https://iris.unisr.it/handle/20.500.11768/148067
Pubblicato in:
JOURNAL OF ULTRASOUND IN MEDICINE
Journal
  • Dati Generali

Dati Generali

URL

https://onlinelibrary.wiley.com/doi/10.1002/jum.14734
  • Utilizzo dei cookie

Realizzato con VIVO | Designed by Cineca | 26.11.1.0