Skip to Main Content (Press Enter)

Logo UNISR
  • ×
  • Home
  • People
  • Outputs
  • Organizations
  • Expertise & Skills
  • Equipment

UNIFIND
Logo UNISR

|

UNIFIND

unisr.it
  • ×
  • Home
  • People
  • Outputs
  • Organizations
  • Expertise & Skills
  • Equipment
  1. Outputs

The Development of an Intelligent Agent to Detect and Non-Invasively Characterize Lung Lesions on CT Scans: Ready for the "Real World"?

Academic Article
Publication Date:
2023
Short description:
The Development of an Intelligent Agent to Detect and Non-Invasively Characterize Lung Lesions on CT Scans: Ready for the "Real World"? / Sollini, M., Kirienko, M., Gozzi, N., Bruno, A., Torrisi, C., Balzarini, L., Voulaz, E., Alloisio, M., Chiti, A.. - In: CANCERS. - ISSN 2072-6694. - 15:2(2023), p. 357. [10.3390/cancers15020357]
abstract:
: (1) Background: Once lung lesions are identified on CT scans, they must be characterized by assessing the risk of malignancy. Despite the promising performance of computer-aided systems, some limitations related to the study design and technical issues undermine these tools' efficiency; an "intelligent agent" to detect and non-invasively characterize lung lesions on CT scans is proposed. (2) Methods: Two main modules tackled the detection of lung nodules on CT scans and the diagnosis of each nodule into benign and malignant categories. Computer-aided detection (CADe) and computer aided-diagnosis (CADx) modules relied on deep learning techniques such as Retina U-Net and the convolutional neural network; (3) Results: Tests were conducted on one publicly available dataset and two local datasets featuring CT scans acquired with different devices to reveal deep learning performances in "real-world" clinical scenarios. The CADe module reached an accuracy rate of 78%, while the CADx's accuracy, specificity, and sensitivity stand at 80%, 73%, and 85.7%, respectively; (4) Conclusions: Two different deep learning techniques have been adapted for CADe and CADx purposes in both publicly available and private CT scan datasets. Experiments have shown adequate performance in both detection and diagnosis tasks. Nevertheless, some drawbacks still characterize the supervised learning paradigm employed in networks such as CNN and Retina U-Net in real-world clinical scenarios, with CT scans from different devices with different sensors' fingerprints and spatial resolution. Continuous reassessment of CADe and CADx's performance is needed during their implementation in clinical practice.
Iris type:
1.1 Articolo in rivista
List of contributors:
Sollini, Martina; Kirienko, Margarita; Gozzi, Noemi; Bruno, Alessandro; Torrisi, Chiara; Balzarini, Luca; Voulaz, Emanuele; Alloisio, Marco; Chiti, Arturo
Authors of the University:
CHITI ARTURO
SOLLINI MARTINA
Handle:
https://iris.unisr.it/handle/20.500.11768/149561
Full Text:
https://iris.unisr.it//retrieve/handle/20.500.11768/149561/165242/Sollini_2023_LILT_real_world_data.pdf
Published in:
CANCERS
Journal
  • Overview

Overview

URL

https://www.mdpi.com/2072-6694/15/2/357
  • Use of cookies

Powered by VIVO | Designed by Cineca | 26.11.0.0