Skip to Main Content (Press Enter)

Logo UNISR
  • ×
  • Home
  • People
  • Outputs
  • Organizations
  • Expertise & Skills

UNIFIND
Logo UNISR

|

UNIFIND

unisr.it
  • ×
  • Home
  • People
  • Outputs
  • Organizations
  • Expertise & Skills
  1. Outputs

Italian multicenter, prospective study to evaluate the negative predictive value of 16- and 64-slice MDCT imaging in patients scheduled for coronary angiography (NIMISCAD-Non Invasive Multicenter Italian Study for Coronary Artery Disease)

Academic Article
Publication Date:
2009
abstract:
This was a prospective, multicenter study designed to evaluate the utility of MDCT in the diagnosis of coronary artery disease (CAD) in patients scheduled for elective coronary angiography (CA) using different MDCT systems from different manufacturers. Twenty national sites prospectively enrolled 367 patients between July 2004 and June 2006. Computed tomography (CT) was performed using a standardized/optimized scan protocol for each type of MDCT system (> or =16 slices) and compared with quantitative CA performed within 2 weeks of MDCT. A total of 284 patients (81%) were studied by 16-slice MDCT systems, while 66 patients (19%) by 64-slice MDCT scanners. The primary analysis was on-site/off-site evaluation of the negative predictive value (NPV) on a per-patient basis. Secondary analyses included on-site evaluation on a per-artery and per-segment basis. On-site evaluation included 327 patients (CAD prevalence 58%). NPV, positive predictive value (PPV), sensitivity, specificity, and diagnostic accuracy (DA) were 0.91 (95% CI 0.85-0.95), 0.91 (95% CI 0.86-0.95), 0.94 (95% CI 0.89-0.97), 0.88 (95% CI 0.81-0.93), and 0.91 (95% CI 0.88-0.94), respectively. Off-site analysis included 295 patients (CAD prevalence 56%). NPV, PPV, sensitivity, specificity, and DA were 0.73 (95% CI 0.65-0.79), 0.93 (95% CI 0.87-0.97), 0.73 (95% CI 0.65-0.79), 0.93 (95% CI 0.87-0.97), and 0.82 (95% CI 0.77-0.86), respectively. The results of this study demonstrate the utility of MDCT in excluding significant CAD even when conducted by centers with varying degrees of expertise and using different MDCT machines.
Iris type:
1.1 Articolo in rivista
List of contributors:
Marano, R; DE COBELLI, Francesco; Floriani, I; Becker, C; Herzog, C; Centonze, M; Morana, G; Gualdi, Gf; Ligabue, G; Pontone, G; Catalano, C; Chiappino, D; Midiri, M; Simonetti, G; Marchisio, F; Olivetti, L; Fattori, R; Bonomo, L; DEL MASCHIO, Alessandro; Nimiscad Study, Grp; Esposito, Antonio
Authors of the University:
DE COBELLI FRANCESCO
ESPOSITO ANTONIO
Handle:
https://iris.unisr.it/handle/20.500.11768/13888
Published in:
EUROPEAN RADIOLOGY
Journal
  • Use of cookies

Powered by VIVO | Designed by Cineca | 26.6.0.0