Skip to Main Content (Press Enter)

Logo UNISR
  • ×
  • Home
  • People
  • Outputs
  • Organizations
  • Expertise & Skills

UNIFIND
Logo UNISR

|

UNIFIND

unisr.it
  • ×
  • Home
  • People
  • Outputs
  • Organizations
  • Expertise & Skills
  1. Outputs

Hyperautofluorescent Ring Pattern in Retinitis Pigmentosa: Clinical Implications and Modifications Over Time

Academic Article
Publication Date:
2023
Short description:
Hyperautofluorescent Ring Pattern in Retinitis Pigmentosa: Clinical Implications and Modifications Over Time / Antropoli, A., Arrigo, A., Bianco, L., Cavallari, E., Bandello, F., Battaglia Parodi, M.. - In: INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE. - ISSN 1552-5783. - 64:12(2023), pp. 1-7. [10.1167/iovs.64.12.8]
abstract:
Purpose: The purpose of this study was to investigate the relation among hyperautofluorescent ring patterns, visual acuity (VA), and optical coherence tomography (OCT) features in patients with retinitis pigmentosa (RP), and to describe its modifications over time. Methods: This was a retrospective, longitudinal, and observational study. Clinical and imaging data from the first and last available visits of patients with a clinical diagnosis of RP were reviewed. The ellipsoid zone (EZ) width was measured on OCT acquisitions. Short-wavelength autofluorescence (SW-AF) images were classified based on the hyperautofluorescent ring pattern as absent, regular, and irregular, and their modifications over the follow-up were described. The VA, EZ width, and progression rate were compared among the three groups. Results: One hundred eight eyes from 54 subjects were included in the study. The hyperautofluorescent ring was not present in 28 eyes (25.9%), appeared regular in 45 eyes (41.7%), and had an irregular pattern in 35 eyes (32.4%). The three groups differed in terms of age, VA, and EZ width (all P < 0.05). Additionally, the absence of a hyperautofluorescent ring indicated a faster rate of progression (P < 0.001). Throughout the follow-up period, 17 eyes (15.7%) experienced a change in the AF pattern, with irregular rings being more commonly affected. Conclusions: The hyperautofluorescent ring is a useful tool to frame patients based on their EZ width and VA. We described its possible modifications over time, the knowledge of which can aid clinicians in the interpretation of imaging finding changes of their patients.
Iris type:
1.1 Articolo in rivista
List of contributors:
Antropoli, Alessio; Arrigo, Alessandro; Bianco, Lorenzo; Cavallari, Elena; Bandello, Francesco; Battaglia Parodi, Maurizio
Authors of the University:
BANDELLO FRANCESCO
BATTAGLIA PARODI MAURIZIO
Handle:
https://iris.unisr.it/handle/20.500.11768/150719
Full Text:
https://iris.unisr.it//retrieve/handle/20.500.11768/150719/171260/i1552-5783-64-12-8_1693820404.5187.pdf
Published in:
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE
Journal
  • Overview

Overview

URL

https://iovs.arvojournals.org/article.aspx?articleid=2792720
  • Use of cookies

Powered by VIVO | Designed by Cineca | 26.7.2.0