Skip to Main Content (Press Enter)

Logo UNISR
  • ×
  • Home
  • Persone
  • Pubblicazioni
  • Facoltà
  • Ambiti Di Ricerca

UNIFIND
Logo UNISR

|

UNIFIND

unisr.it
  • ×
  • Home
  • Persone
  • Pubblicazioni
  • Facoltà
  • Ambiti Di Ricerca
  1. Pubblicazioni

Relationship between crestal bone levels and crown-to-implant ratio of ultra-short implants with a microrough surface: A prospective study with 48 months of follow-up

Articolo
Data di Pubblicazione:
2019
Abstract:
The aim of this cohort study was to investigate the relationship between crestal bone levels and crown-to-implant ratio of ultra-short implants, after functional loading. Sixty patients with single or partial edentulism and alveolar bone atrophy were enrolled and treated between December 2009 and January 2016. Without using bone-grafting procedures, patients were rehabilitated with ultra-short implants characterized by a microrough surface and a 6-mm length. Clinical and anatomical crown-to-implant (C/I) ratios and crestal bone levels (CBL) were measured after a follow-up period ranging from 12 to 72 months; all peri-implant and prosthetic parameters were recorded. The data collected were statistically analyzed (P ¼ .05). A total of 47 patients with 66 ultra-short implants were completely followed up according to described protocol. The mean follow-up was 48.5 6 19.1 months. The mean anatomical C/I ratio was 2.2, while the mean clinical C/I ratio was 2.6 6 0.6 at baseline and 2.8 6 0.6 at the last follow-up appointment. Mean CBL as calculated at the baseline was 0.7 6 0.5 mm, while at the last appointment it measured 1.0 6 0.5 mm. The overall implant-based success rate was 96.9%, and the mean peri-implant bone loss (PBL) was 0.3 6 0.3 mm. No statistically significant relationship was found between anatomical or clinical C/I ratio and PBL. Ultra-short implants appear to offer a predictable solution for implant-prosthetic rehabilitation in patients with edentulism and bone atrophy. A high percentage of implants were successful, with minimal crestal bone loss. The high C/I ratio did not appear to influence either peri-implant bone loss or prosthetic complication rates.
Tipologia CRIS:
1.1 Articolo in rivista
Keywords:
Biomechanical evaluation; Dental implants; Micro roughed surface; Ultra short implants; Cohort Studies; Crowns; Dental Implantation, Endosseous; Dental Prosthesis, Implant-Supported; Follow-Up Studies; Humans; Prospective Studies; Alveolar Bone Loss; Dental Implants; Dental Prosthesis Design
Elenco autori:
Malchiodi, L.; Giacomazzi, E.; Cucchi, A.; Ricciotti, G.; Caricasulo, R.; Bertossi, D.; Gherlone, E.
Autori di Ateneo:
GHERLONE FELICE ENRICO
Link alla scheda completa:
https://iris.unisr.it/handle/20.500.11768/91054
Pubblicato in:
JOURNAL OF ORAL IMPLANTOLOGY
Journal
  • Dati Generali

Dati Generali

URL

https://www.joionline.org/doi/pdf/10.1563/aaid-joi-D-17-00204
  • Utilizzo dei cookie

Realizzato con VIVO | Designed by Cineca | 26.5.1.0