Intra-procedural monitoring protocol using routine transthoracic echocardiography with backup trans-oesophageal probe in transcatheter aortic valve replacement: a single centre experience

Academic Article
Publication Date:
2020
Short description:
Intra-procedural monitoring protocol using routine transthoracic echocardiography with backup trans-oesophageal probe in transcatheter aortic valve replacement: a single centre experience / Stella, S., Melillo, F., Capogrosso, C., Fisicaro, A., Ancona, F., Latib, A., Montorfano, M., Colombo, A., Alfieri, O., Castiglioni, A., Margonato, A., Agricola, E.. - In: EUROPEAN HEART JOURNAL. CARDIOVASCULAR IMAGING. - ISSN 2047-2404. - 21:1(2020), pp. 85-92. [Epub ahead of print] [10.1093/ehjci/jez066]
abstract:
The aim of this study is to describe our 9-year experience in transcatheter aortic valve replacement (TAVR) using transthoracic echocardiography (TTE) as a routine intra-procedural imaging modality with trans-oesophageal echocardiography (TEE) as a backup.
Iris type:
1.1 Articolo in rivista
Keywords:
echocardiography; fluoroscopy; intra-procedural monitoring; transcatheter aortic valve implantation
List of contributors:
Stella, S; Melillo, F; Capogrosso, C; Fisicaro, A; Ancona, F; Latib, A; Montorfano, M; Colombo, A; Alfieri, O; Castiglioni, A; Margonato, A; Agricola, E