  1. Outputs

Internal Guidelines for Reducing Lymph Node Contour Variability in Total Marrow and Lymph Node Irradiation

Academic Article
Publication Date:
2023
Short description:
Internal Guidelines for Reducing Lymph Node Contour Variability in Total Marrow and Lymph Node Irradiation / Dei, D., Lambri, N., Stefanini, S., Vernier, V., Coimbra Brioso, R., Crespi, L., Clerici, E., Bellu, L., De Philippis, C., Loiacono, D., Navarria, P., Reggiori, G., Bramanti, S., Rodari, M., Tomatis, S., Chiti, A., Carlo-Stella, C., Scorsetti, M., Mancosu, P.. - In: CANCERS. - ISSN 2072-6694. - 15:5(2023). [10.3390/cancers15051536]
abstract:
Background: The total marrow and lymph node irradiation (TMLI) target includes the bones, spleen, and lymph node chains, with the latter being the most challenging structures to contour. We evaluated the impact of introducing internal contour guidelines to reduce the inter- and intraobserver lymph node delineation variability in TMLI treatments. Methods: A total of 10 patients were randomly selected from our database of 104 TMLI patients so as to evaluate the guidelines’ efficacy. The lymph node clinical target volume (CTV_LN) was recontoured according to the guidelines (CTV_LN_GL_RO1) and compared to the historical guidelines (CTV_LN_Old). Both topological (i.e., Dice similarity coefficient (DSC)) and dosimetric (i.e., V95 (the volume receiving 95% of the prescription dose) metrics were calculated for all paired contours. Results: The mean DSCs were 0.82 ± 0.09, 0.97 ± 0.01, and 0.98 ± 0.02, respectively, for CTV_LN_Old vs. CTV_LN_GL_RO1, and between the inter- and intraobserver contours following the guidelines. Correspondingly, the mean CTV_LN-V95 dose differences were 4.8 ± 4.7%, 0.03 ± 0.5%, and 0.1 ± 0.1%. Conclusions: The guidelines reduced the CTV_LN contour variability. The high target coverage agreement revealed that historical CTV-to-planning-target-volume margins were safe, even if a relatively low DSC was observed.
Iris type:
1.1 Articolo in rivista
List of contributors:
Dei, Damiano; Lambri, Nicola; Stefanini, Sara; Vernier, Veronica; Coimbra Brioso, Ricardo; Crespi, Leonardo; Clerici, Elena; Bellu, Luisa; De Philippis, Chiara; Loiacono, Daniele; Navarria, Pierina; Reggiori, Giacomo; Bramanti, Stefania; Rodari, Marcello; Tomatis, Stefano; Chiti, Arturo; Carlo-Stella, Carmelo; Scorsetti, Marta; Mancosu, Pietro
Authors of the University:
CHITI ARTURO
Handle:
https://iris.unisr.it/handle/20.500.11768/155858
Full Text:
https://iris.unisr.it//retrieve/handle/20.500.11768/155858/196066/Internal%20Guidelines%20for%20Reducing%20Lymph%20Node%20Contour.pdf
Published in:
CANCERS
Journal
  • Overview

Overview

URL

https://www.mdpi.com/2072-6694/15/5/1536
  • Use of cookies

Powered by VIVO | Designed by Cineca | 26.11.1.0