Skip to Main Content (Press Enter)

Logo UNISR
  • ×
  • Home
  • Persone
  • Pubblicazioni
  • Facoltà
  • Ambiti Di Ricerca

UNIFIND
Logo UNISR

|

UNIFIND

unisr.it
  • ×
  • Home
  • Persone
  • Pubblicazioni
  • Facoltà
  • Ambiti Di Ricerca
  1. Pubblicazioni

Internal Guidelines for Reducing Lymph Node Contour Variability in Total Marrow and Lymph Node Irradiation

Articolo
Data di Pubblicazione:
2023
Citazione:
Internal Guidelines for Reducing Lymph Node Contour Variability in Total Marrow and Lymph Node Irradiation / Dei, Damiano; Lambri, Nicola; Stefanini, Sara; Vernier, Veronica; Coimbra Brioso, Ricardo; Crespi, Leonardo; Clerici, Elena; Bellu, Luisa; De Philippis, Chiara; Loiacono, Daniele; Navarria, Pierina; Reggiori, Giacomo; Bramanti, Stefania; Rodari, Marcello; Tomatis, Stefano; Chiti, Arturo; Carlo-Stella, Carmelo; Scorsetti, Marta; Mancosu, Pietro. - In: CANCERS. - ISSN 2072-6694. - 15:5(2023). [10.3390/cancers15051536]
Abstract:
Background: The total marrow and lymph node irradiation (TMLI) target includes the bones, spleen, and lymph node chains, with the latter being the most challenging structures to contour. We evaluated the impact of introducing internal contour guidelines to reduce the inter- and intraobserver lymph node delineation variability in TMLI treatments. Methods: A total of 10 patients were randomly selected from our database of 104 TMLI patients so as to evaluate the guidelines’ efficacy. The lymph node clinical target volume (CTV_LN) was recontoured according to the guidelines (CTV_LN_GL_RO1) and compared to the historical guidelines (CTV_LN_Old). Both topological (i.e., Dice similarity coefficient (DSC)) and dosimetric (i.e., V95 (the volume receiving 95% of the prescription dose) metrics were calculated for all paired contours. Results: The mean DSCs were 0.82 ± 0.09, 0.97 ± 0.01, and 0.98 ± 0.02, respectively, for CTV_LN_Old vs. CTV_LN_GL_RO1, and between the inter- and intraobserver contours following the guidelines. Correspondingly, the mean CTV_LN-V95 dose differences were 4.8 ± 4.7%, 0.03 ± 0.5%, and 0.1 ± 0.1%. Conclusions: The guidelines reduced the CTV_LN contour variability. The high target coverage agreement revealed that historical CTV-to-planning-target-volume margins were safe, even if a relatively low DSC was observed.
Tipologia CRIS:
1.1 Articolo in rivista
Elenco autori:
Dei, Damiano; Lambri, Nicola; Stefanini, Sara; Vernier, Veronica; Coimbra Brioso, Ricardo; Crespi, Leonardo; Clerici, Elena; Bellu, Luisa; De Philippis, Chiara; Loiacono, Daniele; Navarria, Pierina; Reggiori, Giacomo; Bramanti, Stefania; Rodari, Marcello; Tomatis, Stefano; Chiti, Arturo; Carlo-Stella, Carmelo; Scorsetti, Marta; Mancosu, Pietro
Autori di Ateneo:
CHITI ARTURO
Link alla scheda completa:
https://iris.unisr.it/handle/20.500.11768/155858
Link al Full Text:
https://iris.unisr.it//retrieve/handle/20.500.11768/155858/196066/Internal%20Guidelines%20for%20Reducing%20Lymph%20Node%20Contour.pdf
Pubblicato in:
CANCERS
Journal
  • Dati Generali

Dati Generali

URL

https://www.mdpi.com/2072-6694/15/5/1536
  • Utilizzo dei cookie