Skip to Main Content (Press Enter)

Logo UNISR
  • ×
  • Home
  • Persone
  • Pubblicazioni
  • Facoltà
  • Ambiti Di Ricerca

UNIFIND
Logo UNISR

|

UNIFIND

unisr.it
  • ×
  • Home
  • Persone
  • Pubblicazioni
  • Facoltà
  • Ambiti Di Ricerca
  1. Pubblicazioni

Left atrial appendage closure using AMPLATZER™ devices: A large, multicenter, Italian registry

Articolo
Data di Pubblicazione:
2017
Citazione:
Left atrial appendage closure using AMPLATZER™ devices: A large, multicenter, Italian registry / Berti, Sergio; Santoro, Gennaro; Brscic, Elvis; Montorfano, M; Vignali, Luigi; Danna, Paolo; Tondo, Claudio; D'Amico, Gianpiero; Stabile, Amerigo; Saccà, Salvatore; Patti, Giuseppe; Rapacciuolo, Antonio; Poli, Arnaldo; Golino, Paolo; Magnavacchi, Paolo; De Caterina, Alberto; Meucci, Francesco; Pezzulich, Bruno; Rezzaghi, Marco; Stolcova, Miroslava; Tarantini, Giuseppe. - In: INTERNATIONAL JOURNAL OF CARDIOLOGY. - ISSN 1874-1754. - 248:(2017), pp. 103-107. [10.1016/j.ijcard.2017.07.052]
Abstract:
BACKGROUND: Left atrial appendage occlusion (LAAO) has been proven to be effective for stroke prophylaxis in patients with non-valvular atrial fibrillation (NVAF). We aim to assess the safety and efficacy of LAAO by AMPLATZER™ devices in a large, multicenter, single-nation cohort of NVAF patients at high-risk of stroke and bleeding.METHODS: From December 2008 to April 2015 613 NVAF patients (75.1±8.0years, 62.5% male) underwent LAAO in 15 Italian centers by AMPLATZER™ devices. There were no restrictions on any personal/institutional protocols with respect to indications, pre-procedural planning, device implantation, drug therapy and follow-up. All the baseline characteristics, imaging, procedural and follow-up data were collected in a single dataset.RESULTS: AMPLATZER™ devices were successfully implanted in 95.4% of cases. Major complications occurred during 38 procedures (6.2%) and included more frequently major bleeding (3.3%) and pericardial tamponade (2.0%). At a mean follow-up of 20months, the overall annual rates of stroke and thromboembolic events, including those periprocedural, was 1.67% and 2.90%, respectively, consisting in a reduction in the rate of stroke and TIA of 66% compared with the risk-based expectation. Among the 218 patients undergoing transesophageal echocardiography at 6months of follow-up, device thrombosis was present in 1.8% of the patients whilst a significant or mild to moderate peri-device leak was found in 0.5% and 11.9% of cases, respectively.CONCLUSIONS: In this large, multicenter, single-nation study, LAAO with the AMPLATZER™ devices showed high procedural success, early safety and mid-term efficacy for the prevention of NVAF-related thromboembolism.
Tipologia CRIS:
1.1 Articolo in rivista
Elenco autori:
Berti, Sergio; Santoro, Gennaro; Brscic, Elvis; Montorfano, M; Vignali, Luigi; Danna, Paolo; Tondo, Claudio; D'Amico, Gianpiero; Stabile, Amerigo; Saccà, Salvatore; Patti, Giuseppe; Rapacciuolo, Antonio; Poli, Arnaldo; Golino, Paolo; Magnavacchi, Paolo; De Caterina, Alberto; Meucci, Francesco; Pezzulich, Bruno; Rezzaghi, Marco; Stolcova, Miroslava; Tarantini, Giuseppe
Link alla scheda completa:
https://iris.unisr.it/handle/20.500.11768/143019
Pubblicato in:
INTERNATIONAL JOURNAL OF CARDIOLOGY
Journal
  • Utilizzo dei cookie

Realizzato con VIVO | Designed by Cineca | 26.5.1.0