Skip to Main Content (Press Enter)

Logo UNISR
  • ×
  • Home
  • Persone
  • Pubblicazioni
  • Facoltà
  • Ambiti Di Ricerca

UNIFIND
Logo UNISR

|

UNIFIND

unisr.it
  • ×
  • Home
  • Persone
  • Pubblicazioni
  • Facoltà
  • Ambiti Di Ricerca
  1. Pubblicazioni

Drug-Coated Balloons Versus Second-Generation Drug-Eluting Stents for the Management of Recurrent Multimetal-Layered In-Stent Restenosis

Articolo
Data di Pubblicazione:
2015
Citazione:
Drug-Coated Balloons Versus Second-Generation Drug-Eluting Stents for the Management of Recurrent Multimetal-Layered In-Stent Restenosis / Kawamoto, Hiroyoshi; Ruparelia, Neil; Latib, Azeem; Miyazaki, Tadashi; Sato, Katsumasa; Mangieri, Antonio; Contri, Rachele; Stella, Stefano; Figini, Filippo; Chieffo, Alaide; Carlino, Mauro; Montorfano, M; Colombo, Antonio. - In: JACC. CARDIOVASCULAR INTERVENTIONS. - ISSN 1876-7605. - 8:(2015), pp. 1586-1594. [10.1016/j.jcin.2015.04.032]
Abstract:
OBJECTIVES: This study aimed to investigate the clinical outcomes of patients presenting with recurrent drug-eluting stent (DES) in-stent restenosis (ISR) treated with a second-generation DES or with a drug-coated balloon (DCB).BACKGROUND: To date, there are no reports of DCB treatment and limited data with regard to the efficacy of further DES implantation for recurrent ISR.METHODS: Between January 2008 and December 2013, 171 lesions were assessed for eligibility (82 lesions in the second-generation DES group and 89 lesions in the DCB group).RESULTS: Acute gain was greater in the second-generation DES group (second-generation DES, 2.09 ± 0.53 mm vs. DCBs, 1.60 ± 0.62 mm, p < 0.001). The rates of major adverse cardiac events were comparable (at 1 year, DES 14.0% vs. DCBs 12.3%; at 2 years, DES 28.8% vs. DCBs 43.5%, p = 0.21). Major adverse cardiac event rates were mainly driven by target lesion revascularization (at 1 year, DES 12.5% vs. DCBs 10.9%; at 2 years, DES 27.7% vs. DCBs 38.3%; p = 0.40). Definite scaffold thrombosis occurred in 2 patients (1 patient in each group). Multivariable analysis revealed ISR recurrence within 1 year (hazard ratio: 2.43, 95% confidence interval: 1.14 to 5.18, p = 0.02) and lesion length (per 10-mm increase) (hazard ratio: 1.15, 95% confidence interval: 1.00 to 1.32, p = 0.049) to be independent predictors of TLR.CONCLUSIONS: The results after both treatments were equivalent. ISR recurrence within 1 year of the first reintervention and lesion length were independent predictors of future target lesion revascularization. Larger studies are required to confirm the late (>1 year) differences with regard to clinical outcomes.
Tipologia CRIS:
1.1 Articolo in rivista
Elenco autori:
Kawamoto, Hiroyoshi; Ruparelia, Neil; Latib, Azeem; Miyazaki, Tadashi; Sato, Katsumasa; Mangieri, Antonio; Contri, Rachele; Stella, Stefano; Figini, Filippo; Chieffo, Alaide; Carlino, Mauro; Montorfano, M; Colombo, Antonio
Autori di Ateneo:
CHIEFFO ALAIDE
Link alla scheda completa:
https://iris.unisr.it/handle/20.500.11768/143159
Pubblicato in:
JACC. CARDIOVASCULAR INTERVENTIONS
Journal
  • Utilizzo dei cookie

Realizzato con VIVO | Designed by Cineca | 26.5.2.0