Skip to Main Content (Press Enter)

Logo UNISR
  • ×
  • Home
  • Persone
  • Pubblicazioni
  • Facoltà
  • Ambiti Di Ricerca

UNIFIND
Logo UNISR

|

UNIFIND

unisr.it
  • ×
  • Home
  • Persone
  • Pubblicazioni
  • Facoltà
  • Ambiti Di Ricerca
  1. Pubblicazioni

INVERTED INTERNAL LIMITING MEMBRANE FLAP FOR SMALL-SIZED (<250 µ m) FULL-THICKNESS MACULAR HOLE : Anatomical and Functional Outcome

Articolo
Data di Pubblicazione:
2023
Citazione:
INVERTED INTERNAL LIMITING MEMBRANE FLAP FOR SMALL-SIZED (<250 µ m) FULL-THICKNESS MACULAR HOLE : Anatomical and Functional Outcome / Iuliano, Lorenzo; Corbelli, Eleonora; Bandello, Francesco; Codenotti, Marco. - In: RETINA. - ISSN 0275-004X. - 43:4(2023), pp. 547-554. [10.1097/IAE.0000000000003728]
Abstract:
Purpose:To compare the anatomical and functional outcome of small (mu m) and medium (250-400 mu m) full-thickness macular holes (FTMHs) treated with internal limiting membrane (ILM) inverted flap (IF) or with the standard technique.Methods:Retrospective longitudinal analysis of successfully operated eyes with small or intermediate FTMH. Outcome measures were best-corrected visual acuity (BCVA), microperimetric sensitivity (with fixation stability), and restoration of the external limiting membrane (ELM) and ellipsoid zone (EZ) at 6 months.Results:Fifty small and 50 intermediate eyes with FTMH were included, half of each group (25) treated with the standard technique, half with IF. BCVA increased in every subgroup, similarly within the same stage regardless the technique. Small FTMH treated with IF disclosed inferior foveal sensitivity at 6 months (20.79 +/- 0.48 dB) compared with the standard technique (21.51 +/- 0.79 dB; P = 0.0035). At 1 month, inferior rates of ELM (24%) and EZ (24%) restoration were also found, compared with the standard technique (56% ELM P = 0.0420; 64% EZ P = 0.0095). At 6 months, ELM and EZ were similarly restored.Conclusion:The surgical repair of small FMTH with ILM IF seem to delay the foveal structural repair and to gain an inferior foveal sensitivity compared to the standard technique.
Tipologia CRIS:
1.1 Articolo in rivista
Elenco autori:
Iuliano, Lorenzo; Corbelli, Eleonora; Bandello, Francesco; Codenotti, Marco
Autori di Ateneo:
BANDELLO FRANCESCO
Link alla scheda completa:
https://iris.unisr.it/handle/20.500.11768/148916
Pubblicato in:
RETINA
Journal
  • Dati Generali

Dati Generali

URL

https://journals.lww.com/retinajournal/abstract/2023/04000/inverted_internal_limiting_membrane_flap_for.2.aspx
  • Utilizzo dei cookie

Realizzato con VIVO | Designed by Cineca | 26.5.1.0