Feasibility and reliability of comprehensive three-dimensional transoesophageal echocardiography screening process for transcatheter mitral valve replacement

Academic Article
Publication Date:
2023
Short description:
Feasibility and reliability of comprehensive three-dimensional transoesophageal echocardiography screening process for transcatheter mitral valve replacement / Piroli, F.; Boccellino, A.; Ingallina, G.; Rolando, M.; Melillo, F.; Ancona, F.; Stella, S.; Biondi, F.; Palmisano, A.; Esposito, A.; Denti, P.; Montorfano, M.; Maisano, F.; Castiglioni, A.; Agricola, E.. - In: EUROPEAN HEART JOURNAL. CARDIOVASCULAR IMAGING. - ISSN 2047-2404. - 24:8(2023), pp. 1043-1051. [10.1093/ehjci/jead015]
abstract:
Aims: The procedural planning of transcatheter mitral valve replacement (TMVR) requires a specific imaging assessment to establish patient eligibility. Computed tomography (CT) is considered the reference method. In this setting, data regarding the role of transoesophageal echocardiography (TOE) are lacking. We evaluated the feasibility and reliability of a comprehensive 3D-TOE screening in TMVR candidates. Methods and results: We performed a retrospective observational study including 72 consecutive patients who underwent a pre-procedural CT and 3D-TOE for TMVR evaluation. The measurements of mitral annulus (MA), length of anterior mitral leaflet (AML), native left ventricular outflow tract (LVOT), and predicted neo-LVOT acquired with CT and 3D-TOE were compared using a novel semi-automated software for post processing analysis (3 mensio Structural Heart 10.1 - 3mSH, Pie Medical Imaging, Bilthoven, Netherlands). The final suitability decision was given by the valve manufacturer based on CT measurements and clinical conditions. Among 72 patients screened, all patients had adequate image quality for 3D-TOE analysis. 3D-TOE and CT measurements for AML length (r = 0.97), MA area (r = 0.90), perimeter (r = 0.68), anteroposterior (r = 0.88), and posteromedial-anterolateral (r = 0.74) diameters were found highly correlated, as well as for native LVOT (r = 0.86) and predicted neo-LVOT areas (r = 0.96) (all P-values <0.0001). An almost perfect agreement between CT and 3DTOE was found in assessing the eligibility for TMVR implantation (Cohen kappa 0.83, P < 0.001). Conclusion: 3D-TOE appraisements showed good correlations with CT measurements and high accuracy to predict TMVR screening success.
Iris type:
1.1 Articolo in rivista
List of contributors:
Piroli, F.; Boccellino, A.; Ingallina, G.; Rolando, M.; Melillo, F.; Ancona, F.; Stella, S.; Biondi, F.; Palmisano, A.; Esposito, A.; Denti, P.; Montorfano, M.; Maisano, F.; Castiglioni, A.; Agricola, E.
Authors of the University:
AGRICOLA EUSTACHIO
CASTIGLIONI ALESSANDRO
ESPOSITO ANTONIO
MAISANO FRANCESCO
PALMISANO ANNA
Handle:
https://iris.unisr.it/handle/20.500.11768/149636
Full Text:
https://iris.unisr.it//retrieve/handle/20.500.11768/149636/165522/Feasibility%20and%20reliability%20of%20comprehensive%20three-dimensional%20transoesophageal%20echocardiography%20screening%20process%20for%20transcatheter%20mitral%20valve%20replacement.pdf
Published in:
EUROPEAN HEART JOURNAL. CARDIOVASCULAR IMAGING
Journal
  • Overview

Overview

URL

https://academic.oup.com/ehjcimaging/article/24/8/1043/7043512?login=true