Skip to Main Content (Press Enter)

Logo UNISR
  • ×
  • Home
  • Persone
  • Pubblicazioni
  • Facoltà
  • Ambiti Di Ricerca

UNIFIND
Logo UNISR

|

UNIFIND

unisr.it
  • ×
  • Home
  • Persone
  • Pubblicazioni
  • Facoltà
  • Ambiti Di Ricerca
  1. Pubblicazioni

Automatic Assessment of the 2-Minute Walk Distance for Remote Monitoring of People with Multiple Sclerosis

Articolo
Data di Pubblicazione:
2023
Citazione:
Automatic Assessment of the 2-Minute Walk Distance for Remote Monitoring of People with Multiple Sclerosis / Kontaxis, S.; Laporta, E.; Garcia, E.; Martinis, M.; Leocani, L.; Roselli, L.; Buron, M. D.; Guerrero, A. I.; Zabala, A.; Cummins, N.; Vairavan, S.; Hotopf, M.; Dobson, R. J. B.; Narayan, V. A.; La Porta, M. L.; Costa, G. D.; Magyari, M.; Sorensen, P. S.; Nos, C.; Bailon, R.; Comi, G.. - In: SENSORS. - ISSN 1424-8220. - 23:13(2023). [10.3390/s23136017]
Abstract:
The aim of this study was to investigate the feasibility of automatically assessing the 2-Minute Walk Distance (2MWD) for monitoring people with multiple sclerosis (pwMS). For 154 pwMS, MS-related clinical outcomes as well as the 2MWDs as evaluated by clinicians and derived from accelerometer data were collected from a total of 323 periodic clinical visits. Accelerometer data from a wearable device during 100 home-based 2MWD assessments were also acquired. The error in estimating the 2MWD was validated for walk tests performed at hospital, and then the correlation (r) between clinical outcomes and home-based 2MWD assessments was evaluated. Robust performance in estimating the 2MWD from the wearable device was obtained, yielding an error of less than 10% in about two-thirds of clinical visits. Correlation analysis showed that there is a strong association between the actual and the estimated 2MWD obtained either at hospital (r = 0.71) or at home (r = 0.58). Furthermore, the estimated 2MWD exhibits moderate-to-strong correlation with various MS-related clinical outcomes, including disability and fatigue severity scores. Automatic assessment of the 2MWD in pwMS is feasible with the usage of a consumer-friendly wearable device in clinical and non-clinical settings. Wearable devices can also enhance the assessment of MS-related clinical outcomes.
Tipologia CRIS:
1.1 Articolo in rivista
Keywords:
accelerometer sensor; disability level; fatigue severity; walk tests; wearable device
Elenco autori:
Kontaxis, S.; Laporta, E.; Garcia, E.; Martinis, M.; Leocani, L.; Roselli, L.; Buron, M. D.; Guerrero, A. I.; Zabala, A.; Cummins, N.; Vairavan, S.; Hotopf, M.; Dobson, R. J. B.; Narayan, V. A.; La Porta, M. L.; Costa, G. D.; Magyari, M.; Sorensen, P. S.; Nos, C.; Bailon, R.; Comi, G.
Autori di Ateneo:
LEOCANI ANNUNZIATA MARIA LETIZIA
Link alla scheda completa:
https://iris.unisr.it/handle/20.500.11768/197810
Link al Full Text:
https://iris.unisr.it//retrieve/handle/20.500.11768/197810/322385/sensors-23-06017.pdf
Pubblicato in:
SENSORS
Journal
  • Utilizzo dei cookie

Realizzato con VIVO | Designed by Cineca | 26.5.2.0