Skip to Main Content (Press Enter)

Logo UNISR
  • ×
  • Home
  • Persone
  • Pubblicazioni
  • Facoltà
  • Ambiti Di Ricerca

UNIFIND
Logo UNISR

|

UNIFIND

unisr.it
  • ×
  • Home
  • Persone
  • Pubblicazioni
  • Facoltà
  • Ambiti Di Ricerca
  1. Pubblicazioni

Advanced and traditional chest MRI sequence for the clinical assessment of systemic sclerosis related interstitial lung disease, compared to CT: disease extent analysis and correlations with pulmonary function tests

Articolo
Data di Pubblicazione:
2024
Citazione:
Advanced and traditional chest MRI sequence for the clinical assessment of systemic sclerosis related interstitial lung disease, compared to CT: disease extent analysis and correlations with pulmonary function tests / Landini, N.; Orlandi, M.; Calistri, L.; Nardi, C.; Ciet, P.; Bellando-Randone, S.; Guiducci, S.; Benkert, T.; Panebianco, V.; Morana, G.; Matucci Cerinic, M.; Colagrande, S.. - In: EUROPEAN JOURNAL OF RADIOLOGY. - ISSN 0720-048X. - 170:(2024). [10.1016/j.ejrad.2023.111239]
Abstract:
Background: MRI is a radiation-free emerging alternative to CT in systemic sclerosis related interstitial lung disease (SSc-ILD) assessment. We aimed to compare a T2 radial TSE and a PD UTE MRI sequence with CT in SSc-ILD extent evaluation and correlations with pulmonary function tests (PFT). Material and methods: 29 SSc-ILD patients underwent CT, MRI and PFT. ILD extent was visually assessed. Lin's concordance correlation coefficients (CCC) and Kruskal Wallis test (p-value < 0.05) were computed for inter-method comparison. Patients were divided in limited and extended disease, defining extended ILD with two methods: (A) ILD>30% or 10 % or 20% with FVC%<70%. MRI Sensitivity, Specificity, Positive Predictive Value (PPV), Negative Predictive Value (NPV) and Accuracy were assessed. Pearson correlation coefficients r (p-value<0.025) were computed between ILD extents and PFT (FVC% and DLCO%). Results: Median ILD extents were 11%, 11%, 10% on CT, radial TSE and UTE, respectively. CCC between CT and MRI was 0.95 for both sequences (Kruskal-Wallis p-value=0.64). Sensitivity, Specificity, PPV, NPV and Accuracy in identifying extended disease were: (A) 87.5 %, 100 %, 100 %, 95.5 and 96.6 % with radial TSE and 87.5 %, 95.2 %, 87.5 %, 95.2 and 93.1 % with UTE; (B) 86.7 %, 86.4 %, 66.7 %, 95.0 % and 86.2 % for both sequences. Pearson r of CT, radial TSE and UTE ILD extents with FVC were −0.66, –0.60 and −0.68 with FVC, −0.59, −0.56 and −0.57 with DLCO, respectively (p<0.002). Conclusions: MRI sequences may have similar accuracy to CT to determine SSc-ILD extent and severity, with analogous correlations with PFT.
Tipologia CRIS:
1.1 Articolo in rivista
Elenco autori:
Landini, N.; Orlandi, M.; Calistri, L.; Nardi, C.; Ciet, P.; Bellando-Randone, S.; Guiducci, S.; Benkert, T.; Panebianco, V.; Morana, G.; Matucci Cerinic, M.; Colagrande, S.
Autori di Ateneo:
MATUCCI CERINIC MARCO
Link alla scheda completa:
https://iris.unisr.it/handle/20.500.11768/182196
Pubblicato in:
EUROPEAN JOURNAL OF RADIOLOGY
Journal
  • Dati Generali

Dati Generali

URL

https://www.sciencedirect.com/science/article/pii/S0720048X23005533?via=ihub
  • Utilizzo dei cookie

Realizzato con VIVO | Designed by Cineca | 26.5.1.0