Skip to Main Content (Press Enter)

Logo UNISR
  • ×
  • Home
  • Persone
  • Pubblicazioni
  • Facoltà
  • Ambiti Di Ricerca

UNIFIND
Logo UNISR

|

UNIFIND

unisr.it
  • ×
  • Home
  • Persone
  • Pubblicazioni
  • Facoltà
  • Ambiti Di Ricerca
  1. Pubblicazioni

Coronary Access After TAVR-in-TAVR as Evaluated by Multidetector Computed Tomography

Articolo
Data di Pubblicazione:
2020
Citazione:
Coronary Access After TAVR-in-TAVR as Evaluated by Multidetector Computed Tomography / De Backer, O.; Landes, U.; Fuchs, A.; Yoon, S. -H.; Mathiassen, O. N.; Sedaghat, A.; Kim, W. -K.; Pilgrim, T.; Buzzatti, N.; Ruile, P.; El Sabbagh, A.; Barbanti, M.; Fiorina, C.; Nombela-Franco, L.; Steinvil, A.; Finkelstein, A.; Montorfano, M.; Maurovich-Horvat, P.; Kofoed, K. F.; Blanke, P.; Bunc, M.; Neumann, F. -J.; Latib, A.; Windecker, S.; Sinning, J. -M.; Norgaard, B. L.; Makkar, R.; Webb, J. G.; Sondergaard, L.. - In: JACC: CARDIOVASCULAR INTERVENTIONS. - ISSN 1936-8798. - 13:21(2020), pp. 2528-2538. [10.1016/j.jcin.2020.06.016]
Abstract:
Objectives: The aim of this study was to assess coronary accessibility after transcatheter aortic valve replacement (TAVR)–in–TAVR using multidetector computed tomography. Background: Expanding TAVR to patients with longer life expectancy may involve more frequent bioprosthetic valve failure and need for redo TAVR. Coronary access after TAVR-in-TAVR may be challenging, particularly as the leaflets from the initial transcatheter heart valve (THV) will form a neo-skirt following TAVR-in-TAVR. Methods: In 45 patients treated with different combinations of CoreValve and Evolut (CV/EV) THVs with supra-annular leaflet position and SAPIEN THVs with intra-annular leaflet position, post-TAVR-in-TAVR multidetector computed tomographic scans were analyzed to examine coronary accessibility. Results: After TAVR-in-TAVR, the coronary arteries originated below the top of the neo-skirt in 90% of CV/EV-first cases compared with 67% of SAPIEN-first cases (p = 0.009). For these coronary arteries originating below the top of the neo-skirt, the distance between the THV and the aortic wall was <3 mm in 56% and 25% of CV/EV-first and SAPIEN-first cases, respectively (p = 0.035). Coronary access may be further complicated by THV-THV stent frame strut misalignment in 53% of CV/EV-in-CV/EV cases. The risk for technically impossible coronary access was 27% and 10% in CV/EV-first and SAPIEN-first cases, respectively (p = 0.121). Absence of THV interference with coronary accessibility can be expected in 8% and 33% of CV/EV-first and SAPIEN-first cases, respectively (p = 0.005). Conclusions: Coronary access after TAVR-in-TAVR may be challenging in a significant proportion of patients. THVs with intra-annular leaflet position or low commissural height and large open cells may be preferable in terms of coronary access after TAVR-in-TAVR.
Tipologia CRIS:
1.1 Articolo in rivista
Keywords:
computed tomography; coronary access; transcatheter aortic valve
Elenco autori:
De Backer, O.; Landes, U.; Fuchs, A.; Yoon, S. -H.; Mathiassen, O. N.; Sedaghat, A.; Kim, W. -K.; Pilgrim, T.; Buzzatti, N.; Ruile, P.; El Sabbagh, A.; Barbanti, M.; Fiorina, C.; Nombela-Franco, L.; Steinvil, A.; Finkelstein, A.; Montorfano, M.; Maurovich-Horvat, P.; Kofoed, K. F.; Blanke, P.; Bunc, M.; Neumann, F. -J.; Latib, A.; Windecker, S.; Sinning, J. -M.; Norgaard, B. L.; Makkar, R.; Webb, J. G.; Sondergaard, L.
Link alla scheda completa:
https://iris.unisr.it/handle/20.500.11768/176021
Pubblicato in:
JACC: CARDIOVASCULAR INTERVENTIONS
Journal
  • Utilizzo dei cookie

Realizzato con VIVO | Designed by Cineca | 26.5.1.0