Skip to Main Content (Press Enter)

Logo UNISR
  • ×
  • Home
  • People
  • Outputs
  • Organizations
  • Expertise & Skills

UNIFIND
Logo UNISR

|

UNIFIND

unisr.it
  • ×
  • Home
  • People
  • Outputs
  • Organizations
  • Expertise & Skills
  1. Outputs

Leveraging the potential of 1.0-mm i.d. columns in UHPLC-HRMS-based untargeted metabolomics

Academic Article
Publication Date:
2025
Short description:
Leveraging the potential of 1.0-mm i.d. columns in UHPLC-HRMS-based untargeted metabolomics / La Gioia, D., Salviati, E., Basilicata, M.G., Felici, C., Botrugno, O.A., Tonon, G., Sommella, E., Campiglia, P.. - In: ANALYTICAL AND BIOANALYTICAL CHEMISTRY. - ISSN 1618-2642. - 417:13(2025), pp. 2837-2847. [10.1007/s00216-024-05588-z]
abstract:
Untargeted metabolomics UHPLC-HRMS workflows typically employ narrowbore 2.1-mm inner diameter (i.d.) columns. However, the wide concentration range of the metabolome and the need to often analyze small sample amounts poses challenges to these approaches. Reducing the column diameter could be a potential solution. Herein, we evaluated the performance of a microbore 1.0-mm i.d. setup compared to the 2.1-mm i.d. benchmark for untargeted metabolomics. The 1.0-mm i.d. setup was implemented on a micro-UHPLC system, while the 2.1-mm i.d. on a standard UHPLC, both coupled to quadrupole-orbitrap HRMS. On polar standard metabolites, a sensitivity gain with an average 3.8-fold increase over the 2.1-mm i.d., along with lower LOD (LODavg 1.48 ng/mL vs. 6.18 ng/mL) and LOQ (LOQavg 4.94 ng/mL vs. 20.60 ng/mL), was observed. The microbore method detected and quantified all metabolites at LLOQ with respect to 2.1, also demonstrating good repeatability with lower CV% for retention times (0.29% vs. 0.63%) and peak areas (4.65% vs. 7.27%). The analysis of various samples, in both RP and HILIC modes, including different plasma volumes, dried blood spots (DBS), and colorectal cancer (CRC) patient-derived organoids (PDOs), in full scan-data dependent mode (FS-DDA) reported a significant increase in MS1 and MS2 features, as well as MS/MS spectral matches by 38.95%, 39.26%, and 18.23%, respectively. These findings demonstrate that 1.0-mm i.d. columns in UHPLC-HRMS could be a potential strategy to enhance coverage for low-amount samples while maintaining the same analytical throughput and robustness of 2.1-mm i.d. formats, with reduced solvent consumption.
Iris type:
1.1 Articolo in rivista
List of contributors:
La Gioia, D.; Salviati, E.; Basilicata, M. G.; Felici, C.; Botrugno, O. A.; Tonon, G.; Sommella, E.; Campiglia, P.
Authors of the University:
TONON GIOVANNI
Handle:
https://iris.unisr.it/handle/20.500.11768/185963
Full Text:
https://iris.unisr.it//retrieve/handle/20.500.11768/185963/330033/unpaywall-bitstream--18218404.pdf
Published in:
ANALYTICAL AND BIOANALYTICAL CHEMISTRY
Journal
  • Overview

Overview

URL

https://link.springer.com/article/10.1007/s00216-024-05588-z
  • Use of cookies

Powered by VIVO | Designed by Cineca | 26.9.2.0