  1. Pubblicazioni

MitraClip device automated localization in 3D transesophageal echocardiography via deep learning

Articolo
Data di Pubblicazione:
2025
Citazione:
MitraClip device automated localization in 3D transesophageal echocardiography via deep learning / Munafò, R., Saitta, S., Vicentini, L., Tondi, D., Ruozzi, V., Sturla, F., Ingallina, G., Guidotti, A., Agricola, E., Votta, E.. - In: COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE. - ISSN 0169-2607. - 272:(2025). [10.1016/j.cmpb.2025.109083]
Abstract:
Background and Objective: The MitraClip is the most widely used percutaneous treatment for mitral regurgitation, typically performed under the real-time guidance of 3D transesophageal echocardiography (TEE). However, artifacts and low image contrast in echocardiography hinder accurate clip visualization. This study presents a proof-of-concept of an automated pipeline for clip detection from 3D TEE images acquired in a controlled in vitro simulation environment. Methods: An Attention UNet was employed to segment the device, while a DenseNet classifier predicted its configuration among ten possible states, ranging from fully closed to fully open. Based on the predicted configuration, a template model derived from computer-aided design (CAD) was automatically registered to refine the segmentation and enable quantitative characterization of the device. The pipeline was trained and validated on 196 3D TEE images acquired using a heart simulator, with ground-truth annotations refined through CAD-based templates. Results: The Attention UNet achieved an average surface distance of 0.76 mm and a 95% Hausdorff distance of 2.44 mm for segmentation, while the DenseNet achieved an average weighted F1-score of 0.80 for classification. Post-refinement, segmentation accuracy improved, with average surface distance and 95% Hausdorff distance reduced to 0.69 mm and 1.83 mm, respectively. Conclusion: This pipeline enhanced clip visualization, providing fast and accurate detection with quantitative feedback, potentially improving procedural efficiency and reducing adverse outcomes.
Tipologia CRIS:
1.1 Articolo in rivista
Elenco autori:
Munafò, R.; Saitta, S.; Vicentini, L.; Tondi, D.; Ruozzi, V.; Sturla, F.; Ingallina, G.; Guidotti, A.; Agricola, E.; Votta, E.
Autori di Ateneo:
AGRICOLA EUSTACHIO
Link alla scheda completa:
https://iris.unisr.it/handle/20.500.11768/190236
Link al Full Text:
https://iris.unisr.it//retrieve/handle/20.500.11768/190236/333306/MITRACLIP%20COMPUTER%20METH.pdf