Transseptal BATMAN for High-Risk Valve-in-Ring Procedures: A Case Series

Academic Article
Publication Date:
2024
Short description:
Transseptal BATMAN for High-Risk Valve-in-Ring Procedures: A Case Series / Denti, P.; Saccocci, M.; Buzzatti, N.; Ascione, G.; Margonato, D.; Gatto, P.; Palloshi, A.; Sarais, C.; Longoni, M.; Maisano, F.. - In: JACC. CASE REPORTS. - ISSN 2666-0849. - 29:4(2024). [10.1016/j.jaccas.2023.102200]
abstract:
Valve-in-ring procedures represent a feasible solution for high-risk patients with surgical repair failure. The risk of left ventricular outflow tract obstruction increases the challenge, and transcatheter approaches to prevent it are technically demanding and often do not resolve it. We demonstrate the feasibility and safety of a transseptal balloon-assisted translocation of the anterior mitral leaflet for valve-in-ring implantation.
Iris type:
1.1 Articolo in rivista
List of contributors:
Denti, P.; Saccocci, M.; Buzzatti, N.; Ascione, G.; Margonato, D.; Gatto, P.; Palloshi, A.; Sarais, C.; Longoni, M.; Maisano, F.
Authors of the University:
MAISANO FRANCESCO
Handle:
https://iris.unisr.it/handle/20.500.11768/190577
Full Text:
https://iris.unisr.it//retrieve/handle/20.500.11768/190577/333968/1-s2.0-S2666084923005570-main.pdf
Published in:
JACC. CASE REPORTS
Journal
  • Overview

Overview

URL

https://www.sciencedirect.com/science/article/pii/S2666084923005570?via=ihub
  • Use of cookies

Powered by VIVO | Designed by Cineca | 26.5.1.0