Skip to Main Content (Press Enter)

Logo UNISR
  • ×
  • Home
  • Persone
  • Pubblicazioni
  • Facoltà
  • Ambiti Di Ricerca

UNIFIND
Logo UNISR

|

UNIFIND

unisr.it
  • ×
  • Home
  • Persone
  • Pubblicazioni
  • Facoltà
  • Ambiti Di Ricerca
  1. Pubblicazioni

Macroscopic and microscopic evaluation of a new implant design supporting immediately loaded full arch rehabilitation

Articolo
Data di Pubblicazione:
2012
Citazione:
Macroscopic and microscopic evaluation of a new implant design supporting immediately loaded full arch rehabilitation / Tete, S.; Zizzari, V.; De Carlo, A. D.; Sinjari, B.; Gherlone, E.. - In: ANNALI DI STOMATOLOGIA. - ISSN 1971-1441. - 3:2(2012), pp. 44-50.
Abstract:
The purpose of this study is to evaluate macroscopic and microscopic appearance of a new implant design, with particular emphasis given to the type of prosthesis connection. Two dental implants of the same type (Torque Type®, WINSIX®, BioSAFin. S.r.l.-Ancona, Italy), with sandblasted and acid etched surfaces (Micro Rough Surface®), but differing from each other for the prosthesis connection system, were examined by scanning electron microscope (SEM) analysis at different magnifications: TTI implant, with a hexagonal internal connection, and TTX implant, with a hexagonal external connection. SEM analysis showed that the Torque Type® implant is characterized by a truncated cone shape with tapered tips. The implant body showed a double loop thread and double pitch with blunt tips. For both types of connection, the implant neck was 0.7 mm in height with a 3% taper. This implant design may be able to guarantee osteotomie properties at the time of insertion in a surgical site suitably prepared, a facilitated screwing, thanks to the thread pitch and to the broad and deep draining grooves, thereby ensuring a good primary stability. The different connection design appears defined and precise, in order to ensure a good interface between the fixture and the prosthetic components. Therefore, this design appears to be particularly suitable in cases where a good primary stability is necessary and a precise coupling between endosseous and prosthetic components, as it allows an easy insertion of the fixture even in conditions of reduced bone availability, and in cases of Immediately loaded full-arch rehabilitations.
Tipologia CRIS:
1.1 Articolo in rivista
Keywords:
dental implant; implant connection; Scanning Electron Microscope (SEM)
Elenco autori:
Tete, S.; Zizzari, V.; De Carlo, A. D.; Sinjari, B.; Gherlone, E.
Autori di Ateneo:
GHERLONE FELICE ENRICO
Link alla scheda completa:
https://iris.unisr.it/handle/20.500.11768/195941
Link al Full Text:
https://iris.unisr.it//retrieve/handle/20.500.11768/195941/344783/document.pdf
Pubblicato in:
ANNALI DI STOMATOLOGIA
Journal
  • Dati Generali

Dati Generali

URL

https://www.annalidistomatologia.eu/ads/article/view/161
  • Utilizzo dei cookie

Realizzato con VIVO | Designed by Cineca | 26.5.1.0