Recovery course of persistent posterior subretinal fluid after successful repair of rhegmatogenous retinal detachment

Articolo
Data di Pubblicazione:
2024
Citazione:
Recovery course of persistent posterior subretinal fluid after successful repair of rhegmatogenous retinal detachment / Mansour, A. M.; Lopez-Guajardo, L.; Belotto, S.; Lima, L. H.; Charbaji, A. R.; Schwartz, S. G.; Wu, L.; Smiddy, W. E.; Ascaso, J.; Jurgens, I.; Foster, R. E.; Elnahry, A. G.; Sinawat, S.; Pinilla, I.; Perez-Salvador Garcia, E.; Suarez Leoz, M.; Olivier Pascual, N.; Zago Ribeiro, L.; Arroyo Castillo, R.; Navea, A.; Kadayifcilar, S.; Ellabban, A. A.; Rey, A.; Mansour, H. A.; Tripathy, K.; Kozak, I.; Uwaydat, S. H.; Valero, M. S.; Cobo-Soriano, R.; Diaz-Barreda, M. D.; Monje Fernandez, L.; Gonzalez Del Valle, F.; Lopez Liroz, I.; Vazquez Cruchaga, E.; Fonollosa, A.; Esteban Floria, O.; Relimpio Lopez, M. I.; Shah, G.; Wingelaar, M. J.; Ravani, R.; Donate-Lopez, J.; Rubio Velazquez, E.; Battaglia Parodi, M.. - In: EUROPEAN JOURNAL OF OPHTHALMOLOGY. - ISSN 1120-6721. - 34:4(2024), pp. 1217-1227. [10.1177/11206721231210693]
Abstract:
Purpose: To investigate best corrected visual acuity (BCVA), subretinal fluid (SRF) absorption time or ellipsoid zone (EZ) restoration time and various variables in patients with persistent SRF after successful primary repair of rhegmatogenous retinal detachment (RRD). Methods: This retrospective multicenter study allowed independent analysis of the healing pattern by two observers based on composite of serial cross-sectional macular optical coherence tomography (OCT) scans. Univariate and multivariate analyses were implemented. Results: One hundred and three cases had persistent SRF after pars plana vitrectomy, scleral buckling, or pneumatic retinopexy. By univariate analysis, SRF resolution time correlated positively with the number of retinal breaks (p < 0.001) and with increased myopia (p = 0.011). Using multivariate analysis, final BCVA (log MAR) correlated positively with age, duration of RRD, initial BCVA (OR = 3.28; [95%CI = 1.44–7.47]; p = 0.015), and SRF resolution time (OR = 0.46 [95%CI 0.21–1.05]; p = 0.049). EZ restoration time was longer with increasing number of retinal tears (OR = 0.67; [95%CI 0.29–1.52]; p = 0.030), worse final BCVA, and presence of macula-off RRD (OR = 0.26; [95%CI 0.08–0.88]; p = 0.056). SRF resolution time correlated marginally with prone position. Conclusions: Residual posterior SRF is more common in eyes with multiple breaks or in myopic eyes. Final BCVA is better in younger subjects and in eyes with shorter duration of RRD. Persistent SRF is a self-limited disorder with a mean resolution of 11.2 months with good visual prognosis improving from a mean baseline logMAR of 1.08 to 0.25 at one year.
Tipologia CRIS:
1.1 Articolo in rivista
Elenco autori:
Mansour, A. M.; Lopez-Guajardo, L.; Belotto, S.; Lima, L. H.; Charbaji, A. R.; Schwartz, S. G.; Wu, L.; Smiddy, W. E.; Ascaso, J.; Jurgens, I.; Foster, R. E.; Elnahry, A. G.; Sinawat, S.; Pinilla, I.; Perez-Salvador Garcia, E.; Suarez Leoz, M.; Olivier Pascual, N.; Zago Ribeiro, L.; Arroyo Castillo, R.; Navea, A.; Kadayifcilar, S.; Ellabban, A. A.; Rey, A.; Mansour, H. A.; Tripathy, K.; Kozak, I.; Uwaydat, S. H.; Valero, M. S.; Cobo-Soriano, R.; Diaz-Barreda, M. D.; Monje Fernandez, L.; Gonzalez Del Valle, F.; Lopez Liroz, I.; Vazquez Cruchaga, E.; Fonollosa, A.; Esteban Floria, O.; Relimpio Lopez, M. I.; Shah, G.; Wingelaar, M. J.; Ravani, R.; Donate-Lopez, J.; Rubio Velazquez, E.; Battaglia Parodi, M.
Autori di Ateneo:
BATTAGLIA PARODI MAURIZIO
Link alla scheda completa:
https://iris.unisr.it/handle/20.500.11768/198258
Pubblicato in:
EUROPEAN JOURNAL OF OPHTHALMOLOGY
Journal