Skip to Main Content (Press Enter)

Logo UNISR
  • ×
  • Home
  • Persone
  • Pubblicazioni
  • Facoltà
  • Ambiti Di Ricerca

UNIFIND
Logo UNISR

|

UNIFIND

unisr.it
  • ×
  • Home
  • Persone
  • Pubblicazioni
  • Facoltà
  • Ambiti Di Ricerca
  1. Pubblicazioni

Repeatability of Quantitative Autofluorescence Imaging in a Multicenter Study Involving Patients With Recessive Stargardt Disease 1

Articolo
Data di Pubblicazione:
2023
Citazione:
Repeatability of Quantitative Autofluorescence Imaging in a Multicenter Study Involving Patients With Recessive Stargardt Disease 1 / Dhooge, P. P. A.; Moller, P. T.; Meland, N.; Stingl, K.; Boon, C. J. F.; Lotery, A. J.; Parodi, M. B.; Herrmann, P.; Klein, W.; Fsadni, M. G.; Wheeler-Schilling, T. H.; Holz, F. G.; Hoyng, C. B.; Schmitz-Valckenberg, S.. - In: TRANSLATIONAL VISION SCIENCE & TECHNOLOGY. - ISSN 2164-2591. - 12:2(2023). [10.1167/tvst.12.2.1]
Abstract:
Purpose: This study assesses the repeatability of quantitative autofluorescence (qAF) in a multicenter setting and evaluates qAF as the end point for clinical trials in recessive Stargardt disease 1 (STGD1). Methods: A total of 102 patients with STGD1 underwent qAF imaging as part of the Stargardt Remofuscin Treatment Trial (STARTT; EudraCT No. 2018-001496-20). For 166 eyes, we obtained qAF imaging at 2 visits, with 2 recordings per visit. The qAF8 values were independently determined by the study site and a central reading center. Intra-and inter-visit reproducibility, as well as interobserver (study site versus reading center) reproducibility were obtained using intraclass correlation (ICC), one-sample t-test, and Bland-Altman coefficient of repeatability. Results: The qAF repeatability was ± 26.1% for intra-visit, ± 40.5% for inter-visit, and ± 20.2% for the interobserver reproducibility measures. Intra-visit repeatability was good to excellent for all sites (ICC of 0.88–0.96). Variability between visits was higher with an overall ICC of 0.76 (0.69–0.81). We observed no significant difference in qAF values across sites between visits (7.06 ± 93.33, P = 0.238). Conclusions: Real-life test-retest variability of qAF is higher in this set of data than previ-ously reported in single center settings. With improved operator training and by select-ing the better of two recordings for evaluation, qAF serves as a useful method for assessing changes in autofluorescence signal. Translational Relevance: The qAF can be adopted as a clinical trial end point, but steps to counterbalance variability should be considered.
Tipologia CRIS:
1.1 Articolo in rivista
Elenco autori:
Dhooge, P. P. A.; Moller, P. T.; Meland, N.; Stingl, K.; Boon, C. J. F.; Lotery, A. J.; Parodi, M. B.; Herrmann, P.; Klein, W.; Fsadni, M. G.; Wheeler-Schilling, T. H.; Holz, F. G.; Hoyng, C. B.; Schmitz-Valckenberg, S.
Autori di Ateneo:
BATTAGLIA PARODI MAURIZIO
Link alla scheda completa:
https://iris.unisr.it/handle/20.500.11768/198268
Link al Full Text:
https://iris.unisr.it//retrieve/handle/20.500.11768/198268/349911/i2164-2591-12-2-1_1675163056.09782.pdf
Pubblicato in:
TRANSLATIONAL VISION SCIENCE & TECHNOLOGY
Journal
  • Dati Generali

Dati Generali

URL

https://tvst.arvojournals.org/article.aspx?articleid=2785327
  • Utilizzo dei cookie

Realizzato con VIVO | Designed by Cineca | 26.5.1.0