Mycobacterium chimaera in heater–cooler units: new technical approach for treatment, cleaning and disinfection protocol

Articolo
Data di Pubblicazione:
2018
Abstract:
Mycobacterium chimaera infections have mainly been associated with the heater-cooler unit (HCU) and, ultimately, linked to contaminated aerosols in the operation room. The contamination status of HCUs seems to be influenced by the maintenance, therefore, according to the manufacturer’s recommendations, peracetic acid (Puristeril) was introduced to increase HCU cleaning and disinfection protocol maintenance. Aerosol dispersion from Puristeril during maintenance can cause adverse effects to nearby workers. We aim to describe our technique to reduce the impact of Puristeril on operating room staff and to limit dispersion of its aerosol in the environment by performing the cleaning procedure through a closed circuit.
Tipologia CRIS:
1.1 Articolo in rivista
Keywords:
cardiac surgery; cardiopulmonary bypass; heater-cooler unit; heater-exchanger; Mycobacterium chimaera; Radiology, Nuclear Medicine and Imaging; Safety Research; Cardiology and Cardiovascular Medicine; Advanced and Specialized Nursing
Elenco autori:
Colangelo, Nicola; Giambuzzi, Ilaria; Moro, Matteo; Pasqualini, Neva; Aina, Alessandro; De Simone, Francesco; Blasio, Andrea; Alfieri, Ottavio; Castiglioni, Alessandro; De Bonis, Michele
Autori di Ateneo:
CASTIGLIONI ALESSANDRO
DE BONIS MICHELE
Link alla scheda completa:
https://iris.unisr.it/handle/20.500.11768/85218
Pubblicato in:
PERFUSION-UK