Development of a prototype anti-pollution filter for volatile anesthetics

Articolo
Data di Pubblicazione:
2020
Citazione:
Development of a prototype anti-pollution filter for volatile anesthetics / Nigro Neto, C.; Andrade, A. J. P.; Leal, E.; Bezerra, F. J. L.; Lomivorotov, V.; Landoni, G.. - In: INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS. - ISSN 0391-3988. - 43:7(2020), pp. 476-481. [10.1177/0391398819895991]
Abstract:
Introduction: The use of volatile agents during cardiopulmonary bypass allows a “single drug anesthesia” and is associated with reduced peak postoperative troponin levels. Connecting the exhaust systems to the oxygenator’s gas outlet port is mandatory and allows to prevent operating room (but not atmospheric) pollution by volatile agents. The aim of this study was to create a prototype filter for volatile agents and to test its adsorption efficacy during an ex-vivo simulated conventional cardiopulmonary bypass test. Methods: We carried out bench tests to conceive a prototype filter that could prevent room and environment pollution without damaging membrane oxygenators. We performed the tests at the Engineering Center for Circulatory Assistance Laboratory, Dante Pazzanese Institute of Cardiology, São Paulo, Brazil. Bench tests included simulation of integral adsorption tests, filter dimensions and design, flow versus pressure curve, sizing, and tightness. Results: Calgon AT 410 was the best kind of activated charcoal granules for adsorption of sevoflurane, isoflurane, and desflurane. Filter dimension tests showed that a chamber of 30-cm width over 10-cm diameter filled with 200 g of the Calgon AT410 granules was the minimum required to fully adsorb sevoflurane for 90 min. Adsorption tests showed that the prototype filter fully adsorbed isoflurane in 100 ± 2.3 min, sevoflurane in 95 ± 3.4 min, and desflurane in 95 ± 4.3 min. Conclusion: The new version of our prototype filter adsorbed most of the volatile anesthetics agents during an ex-vivo simulated conventional cardiopulmonary bypass test.
Tipologia CRIS:
1.1 Articolo in rivista
Elenco autori:
Nigro Neto, C.; Andrade, A. J. P.; Leal, E.; Bezerra, F. J. L.; Lomivorotov, V.; Landoni, G.
Autori di Ateneo:
LANDONI GIOVANNI
Link alla scheda completa:
https://iris.unisr.it/handle/20.500.11768/97394
Pubblicato in:
INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS
Journal
  • Dati Generali

Dati Generali

URL

https://journals.sagepub.com/home/jao
  • Utilizzo dei cookie

Realizzato con VIVO | Designed by Cineca | 26.5.1.0