Skip to Main Content (Press Enter)

Logo UNISR
  • ×
  • Home
  • Persone
  • Pubblicazioni
  • Facoltà
  • Ambiti Di Ricerca

UNIFIND
Logo UNISR

|

UNIFIND

unisr.it
  • ×
  • Home
  • Persone
  • Pubblicazioni
  • Facoltà
  • Ambiti Di Ricerca
  1. Pubblicazioni

Non-paroxysmal atrial fibrillation mapping: characterization of the electrophysiological substrate using a novel integrated mapping technique

Articolo
Data di Pubblicazione:
2019
Abstract:
AIMS: Clinical outcomes after radiofrequency catheter ablation (RFCA) remain suboptimal in the treatment of non-paroxysmal atrial fibrillation (AF). Electrophysiological mapping may improve understanding of the underlying mechanisms. To describe the arrhythmia substrate in patients with persistent (Pers) and long-standing persistent (LSPers) AF, undergoing RFCA, using an integrated mechanism mapping technique. METHODS AND RESULTS: Patients underwent high-density electroanatomical mapping before and after catheter ablation. Integrated maps characterized electrogram (EGM) cycle length (CL) in regions with repetitive-regular (RR) activations, stable wavefront propagation, fragmentation, and peak-to-peak bipolar voltage. Among 83 patients (72% male, 60 ± 11 years old), RR activations were identified in 376 regions (mean CL 180 ± 31 ms). PersAF patients (n = 43) showed more RR sites per patient (5.3 ± 2.4 vs. 3.7 ± 2.1, P = 0.002) with faster CL (166 ± 29 vs. 190 ± 29 ms; P < 0.001) and smaller surface area of fragmented EGMs (15 ± 14% vs. 27 ± 17%, P < 0.001) compared with LSPersAF. The post-ablation map in 50 patients remaining in AF, documented reduction of the RR activities per patient (1.5 ± 0.7 vs. 3.7 ± 1.4, P < 0.001) and area of fragmentation (22 ± 17% vs. 8 ± 9%, P < 0.001). Atrial fibrillation termination during ablation occurred at RR sites (0.48 ± 0.24 mV; 170.5 ± 20.2 ms CL) in 31/33 patients (94%). At the latest follow-up, arrhythmia freedom was higher among patients receiving ablation >75% of RR sites (Q4 82.6%, Q3 63.1%, Q2 35.1%, and Q1 0%; P < 0.001). CONCLUSION: The integrated mapping technique allowed characterization of multiple arrhythmic substrates in non-paroxysmal AF patients. This technique might serve as tool for a substrate-targeted ablation approach.
Tipologia CRIS:
1.1 Articolo in rivista
Keywords:
Ablation; Atrial fibrillation; Electrophysiological substrate; High-density electroanatomical mapping; Persistent atrial fibrillation; Cardiac Electrophysiology; Catheter Ablation; Electrophysiological Phenomena; Female; Humans; Male; Middle Aged; Perioperative Care; Reproducibility of Results; Treatment Outcome; Atrial Fibrillation; Body Surface Potential Mapping; Electrophysiologic Techniques, Cardiac
Elenco autori:
Ciconte, G.; Vicedomini, G.; Li, W.; Mangual, J. O.; Mcspadden, L.; Ryu, K.; Saviano, M.; Vitale, R.; Conti, M.; Calovic, Z.; Santinelli, V.; Pappone, C.
Autori di Ateneo:
CICONTE GIUSEPPE
PAPPONE CARLO
Link alla scheda completa:
https://iris.unisr.it/handle/20.500.11768/112456
Pubblicato in:
EUROPACE
Journal
  • Utilizzo dei cookie

Realizzato con VIVO | Designed by Cineca | 26.5.1.0