Skip to Main Content (Press Enter)

Logo UNISR
  • ×
  • Home
  • Persone
  • Pubblicazioni
  • Facoltà
  • Ambiti Di Ricerca

UNIFIND
Logo UNISR

|

UNIFIND

unisr.it
  • ×
  • Home
  • Persone
  • Pubblicazioni
  • Facoltà
  • Ambiti Di Ricerca
  1. Pubblicazioni

Long-term results of tricuspid annuloplasty with 3-dimensional-shaped rings: Effective and durable!

Articolo
Data di Pubblicazione:
2021
Abstract:
OBJECTIVES: 3-Dimensional (3D)-shaped rings are largely adopted for tricuspid annuloplasty, but evidence about their long-term results is scanty. The goal of this study was to analyse the long-term results of tricuspid annuloplasty with 3D-shaped rings. MATERIALS AND METHODS: A retrospective review of our prospectively maintained database was carried out to identify all patients who underwent tricuspid valve repair with 3D-shaped rings between January 2011 and December 2014. Kaplan-Meier methods were used to analyse long-term survival. Cumulative incidence function using death as the competitive outcome was used to estimate cardiac death. RESULTS: A total of 168 patients were identified. The median age was 66 years. Eighty-two patients (49%) were in advanced New York Heart Association functional class III-IV. Atrial fibrillation (AF) was present in 101 (60%); the median ejection fraction was 60%. In 82 (49%) patients, a Medtronic 3D Contour annuloplasty ring was employed; in the remaining 86 (51%) patients, an Edwards MC3 ring was used. Cumulative incidence function of cardiac death, with non-cardiac death as a competing risk, was 1.9 ± 1.1%, 95% confidence interval (CI) (0.51-4.95) at 7 years. The cumulative incidence function of recurrence of tricuspid regurgitation (TR) ≥2+ at 7 years was 14 ± 3.17%, 95% CI (8.49-20.82). Recurrence of TR ≥2+ at 7 years was not significantly different between the Medtronic 3D Contour and the Edwards MC3 rings (P = 0.3). AF was identified as the only independent predictor of recurrence of TR ≥2+. CONCLUSIONS: 3D-shaped rings are effective and durable. TR recurrence was relatively low at 7 years and usually moderate (2+/4+) without a significant difference between the 2 types of rings. The role of AF as a predictor of TR recurrence was confirmed.
Tipologia CRIS:
1.1 Articolo in rivista
Keywords:
3D shaped rings; Tricuspid annuloplasty; Tricuspid regurgitation; Tricuspid valve repair; Aged; Humans; Retrospective Studies; Treatment Outcome; Tricuspid Valve; Cardiac Valve Annuloplasty; Heart Valve Prosthesis; Heart Valve Prosthesis Implantation; Tricuspid Valve Insufficiency
Elenco autori:
Carino, D.; Zancanaro, E.; Lapenna, E.; Ruggeri, S.; Denti, P.; Iaci, G.; Buzzatti, N.; Calabrese, M. C.; Nascimbene, S.; Sala, A.; Castiglioni, A.; Alfieri, O.; De Bonis, M.
Autori di Ateneo:
CASTIGLIONI ALESSANDRO
DE BONIS MICHELE
Link alla scheda completa:
https://iris.unisr.it/handle/20.500.11768/118868
Pubblicato in:
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY
Journal
  • Utilizzo dei cookie

Realizzato con VIVO | Designed by Cineca | 26.5.1.0